Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1998 Jul;66(1):19-24; discussion 24-5.
doi: 10.1016/s0003-4975(98)00390-7.

Endovascular stent graft repair for aneurysms on the descending thoracic aorta

Affiliations
Comparative Study

Endovascular stent graft repair for aneurysms on the descending thoracic aorta

M Ehrlich et al. Ann Thorac Surg. 1998 Jul.

Abstract

Background: The traditional treatment of aneurysms of the descending thoracic aorta includes posterolateral thoracotomy and aortic replacement with a prosthetic graft. In this study, we report our experiences and results in endovascular stent graft placement as an alternative to surgical repair.

Methods: Between January 1989 and July 1997, a total of 68 patients (24 women) underwent replacement of the thoracic aorta. Mean age at operation was 51 years. Fifty-eight patients underwent conventional surgical treatment. All of these patients were suitable candidates for endovascular stenting; however, no stent graft material was available at the time of operation. Ten patients (1 chronic dissection, 9 atherosclerotic aneurysm) received in the past 8 months the first commercially manufactured endovascular stent graft. The mean diameter of the aneurysms in this group was 7 cm (range, 6 to 8 cm). Two stent patients were operated on using only spinal cord analgesia. All stent grafts were custom designed for each of the 10 patients.

Results: The 30-day mortality in the conventional group was 31% versus 10% in the stent group. Mean length of intervention was 320 minutes in the conventional group versus 150 minutes in the endovascular group. Spinal cord injury occurred in 5 patients (12%) in the surgical group, whereas none of the stented patients developed any neurologic sequelae. Mean intensive care unit stay was 13 days, followed by a mean of 10 days on a ward in the first group compared to 4 days in the intensive care unit and 6 days on the ward in the stent group. One stent was required in 2 patients, two stents were required in 3 patients, and four stents were deployed in 5 patients of our series. Five patients required transposition of the left subclavian artery to achieve a sufficient neck for the proximal placement of the stent. There was complete thrombosis of the thoracic aortic aneurysm surrounding the stent graft in 8 patients (80%). Two patients required restenting as a result of leakage (20%). Stent graft placing was performed through the femoral artery in 8 patients, whereas access was only achieved through the abdominal aorta in 2 patients.

Conclusions: These preliminary results demonstrate that endovascular stent graft replacement might be a promising, cheaper, and safe alternative method in selected patients with descending thoracic aneurysms.