Red cell membrane damage
- PMID: 9697059
Red cell membrane damage
Abstract
Turbulent shear stresses created by the fluid dynamic characteristics of prosthetic valves cause damage to blood cells. Platelet activation and damage is extensively described and red blood cell hemolysis is reported in a significant number of valve replacements. Most of these studies have evaluated hemolysis in normal red cells and relate to different valves or replacement procedures rather than the red cell. Prehemolytic red cell damage is rarely considered and only few studies describe the effect of valve replacement on patients with red cell disorders. While hemolytic anemia is the ultimate end-point of valve-induced red cell damage, loss of red cells goes hand in hand with the formation of red cell-derived damaged membranes. It can be hypothesized that alterations (in subpopulations) of red cells and generation of red cell remnants due to the increased shear stress could have a profound physiologic effect before hemolytic anemia is apparent. In patients with red cell disorders, alterations in the red cell membrane suggest that red cell damage will be more pronounced after valve replacement. In this review, determinants of normal and abnormal red cell behavior under shear are discussed as well as some of the possible physiologic consequences of the formation of damaged red cell membranes.
Similar articles
-
Prosthesis-induced hemolysis: mechanisms and quantification of shear stress.J Heart Valve Dis. 1998 Jul;7(4):376-86. J Heart Valve Dis. 1998. PMID: 9697058 Review.
-
Prosthetic heart valves' mechanical loading of red blood cells in patients with hereditary membrane defects.J Biomech. 2005 Aug;38(8):1557-65. doi: 10.1016/j.jbiomech.2004.11.020. Epub 2005 Jan 19. J Biomech. 2005. PMID: 15958211
-
Leakage flow at mechanical heart valve prostheses: improved washout or increased blood damage?J Heart Valve Dis. 1999 May;8(3):312-23. J Heart Valve Dis. 1999. PMID: 10399668
-
Deformability of red blood cells and its relation to blood trauma in rotary blood pumps.Artif Organs. 2007 May;31(5):352-8. doi: 10.1111/j.1525-1594.2007.00392.x. Artif Organs. 2007. PMID: 17470204
-
Deformability and viability of irradiated red cells.Ann Ist Super Sanita. 2007;43(2):176-85. Ann Ist Super Sanita. 2007. PMID: 17634667 Review.
Cited by
-
Plasma membrane integrity: implications for health and disease.BMC Biol. 2021 Apr 13;19(1):71. doi: 10.1186/s12915-021-00972-y. BMC Biol. 2021. PMID: 33849525 Free PMC article. Review.
-
Sarpogrelate reduces mechanical hemolysis in patients with heart valve prostheses.Jpn J Thorac Cardiovasc Surg. 2000 Dec;48(12):769-74. doi: 10.1007/BF03218250. Jpn J Thorac Cardiovasc Surg. 2000. PMID: 11197820
-
The Effect of Polymeric Nanoparticles on Biocompatibility of Carrier Red Blood Cells.PLoS One. 2016 Mar 22;11(3):e0152074. doi: 10.1371/journal.pone.0152074. eCollection 2016. PLoS One. 2016. PMID: 27003833 Free PMC article.
-
Effect of picroside II on erythrocyte deformability and lipid peroxidation in rats subjected to hind limb ischemia reperfusion injury.Drug Des Devel Ther. 2016 Mar 1;10:927-31. doi: 10.2147/DDDT.S95418. eCollection 2016. Drug Des Devel Ther. 2016. PMID: 27041996 Free PMC article.
-
A quantitative comparison of mechanical blood damage parameters in rotary ventricular assist devices: shear stress, exposure time and hemolysis index.J Biomech Eng. 2012 Aug;134(8):081002. doi: 10.1115/1.4007092. J Biomech Eng. 2012. PMID: 22938355 Free PMC article.