Requirements for the electronic crossmatch
- PMID: 9704475
- DOI: 10.1111/j.1423-0410.1998.tb05450.x
Requirements for the electronic crossmatch
Abstract
With the integration of laboratory information systems into transfusion services, it is now possible to develop standard operating procedures (SOPs) for an electronic crossmatch (EXM) to replace the immediate-spin crossmatch for detecting ABO incompatibility between the blood sample submitted for pre-transfusion testing and the donor unit selected for transfusion. Essential to the safety of an EXM are requirements that: 1) the computer contains logic to prevent assignment and release of ABO incompatible blood; 2) no clinically significant antibodies are detected in the recipient's serum/plasma and there is no record of previous detection of such antibodies; 3) there are concordant results of at least two determinations of the recipient's ABO type on record, one of which is from a current sample; 4) critical elements of the system have been validated on-site; and, 5) there are mechanisms to verify the correct entry of data prior to release of blood. EXM procedures are in use in at least 10 North American facilities, Scandinavia, Hong Kong and Australia. Some provide blood at remote sites lacking laboratory services. Experience has shown that a combination of properly programmed computer software and carefully developed SOPs can provide a safe and efficient means of detecting ABO incompatibility without performing a serological crossmatch.
Similar articles
-
Electronic verification of donor-recipient compatibility: the computer crossmatch.Transfusion. 1994 Feb;34(2):105-9. doi: 10.1046/j.1537-2995.1994.34294143935.x. Transfusion. 1994. PMID: 8310478
-
Experiences with "self service" electronic blood banking.Vox Sang. 1998;74 Suppl 2:427-9. doi: 10.1111/j.1423-0410.1998.tb05452.x. Vox Sang. 1998. PMID: 9704477 Review.
-
Guidelines for pre-transfusion compatibility procedures in blood transfusion laboratories. BCSH Blood Transfusion Task Force.Transfus Med. 1996 Sep;6(3):273-83. Transfus Med. 1996. PMID: 8885158 No abstract available.
-
The United Kingdom National External Quality Assessment Scheme (blood transfusion laboratory practice): trends in proficiency and practice between 1985 and 2000.Transfus Med. 2002 Feb;12(1):11-23. doi: 10.1046/j.1365-3148.2002.00353.x. Transfus Med. 2002. PMID: 11967133
-
The computer crossmatch: a safe alternative to the serological crossmatch.Transfus Med. 2000 Dec;10(4):251-6. doi: 10.1046/j.1365-3148.2000.00274.x. Transfus Med. 2000. PMID: 11123808 Review.
Cited by
-
Use of remote blood releasing system for red cell transfusion in hospice care center.SAGE Open Med Case Rep. 2016 Jun 28;4:2050313X16654422. doi: 10.1177/2050313X16654422. eCollection 2016. SAGE Open Med Case Rep. 2016. PMID: 27489720 Free PMC article.
-
Reducing unnecessary preoperative blood orders and costs by implementing an updated institution-specific maximum surgical blood order schedule and a remote electronic blood release system.Anesthesiology. 2014 Sep;121(3):501-9. doi: 10.1097/ALN.0000000000000338. Anesthesiology. 2014. PMID: 24932853 Free PMC article.
-
Safety issues related to the electronic cross-matching of blood in mainland China: A prospective cohort study involving cross-matching of 40,228 blood samples.Medicine (Baltimore). 2019 Aug;98(35):e16703. doi: 10.1097/MD.0000000000016703. Medicine (Baltimore). 2019. PMID: 31464901 Free PMC article.
-
Type and screen policy in the blood bank: Is AHG cross-match still required? A study at a multispecialty corporate hospital in India.Asian J Transfus Sci. 2011 Jul;5(2):153-6. doi: 10.4103/0973-6247.83242. Asian J Transfus Sci. 2011. PMID: 21897595 Free PMC article.
-
Patients' positive identification systems.Blood Transfus. 2009 Oct;7(4):313-8. doi: 10.2450/2009.0001-09. Blood Transfus. 2009. PMID: 20011643 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical