Controlled comparative evaluation of BacT/Alert FAN and ESP 80A aerobic media as means for detecting bacteremia and fungemia
- PMID: 9705414
- PMCID: PMC105184
- DOI: 10.1128/JCM.36.9.2686-2689.1998
Controlled comparative evaluation of BacT/Alert FAN and ESP 80A aerobic media as means for detecting bacteremia and fungemia
Abstract
During a one-year period, a total of 6,305 blood cultures were processed in a tertiary-care teaching hospital; 6 to 12 ml of blood was inoculated into both a BacT/Alert Fan aerobic bottle and an ESP 80A aerobic bottle. The FAN aerobic bottle contains an antimicrobial-absorbing material; the 80A aerobic bottle does not. Bottles were processed on their respective continuous-monitoring blood culture instruments for up to five days of incubation. Four hundred thirty-three cultures (6.9%) representing 301 septic episodes in 235 different patients yielded 490 bacteria or yeasts thought to be clinically significant. Two hundred seventy-five of the 433 presumed clinically significant positive cultures (63.5%) representing 195 septic episodes and yielding 301 isolates were positive in both FAN and 80A bottles. One hundred nine significant positive cultures (25.2%) (i.e., cultures positive with an organism judged to be of probable clinical significance) from 70 septic episodes yielded 126 isolates only in FAN bottles. Conversely, the 80A bottle was exclusively positive in 49 instances (11.3%), representing 36 septic episodes and yielding 63 isolates. The higher rates of significant positive blood cultures, numbers of septic episodes documented, and numbers of isolates recovered in FAN bottles versus 80A bottles were all statistically significant (P < 0.05). Enhanced rates of detection of presumed clinically significant isolates in FAN bottles were largely accounted for by Staphylococcus aureus, members of the Enterobacteriaceae, and non-Pseudomonas aeruginosa miscellaneous gram-negative bacilli from patients receiving antimicrobial therapy at the time blood cultures were obtained. Enhanced recovery of one organism group, the beta-hemolytic streptococci, occurred in 80A. With one exception, detection times were essentially equivalent in the two systems. The single exception pertained to streptococci and enterococci, which were recovered significantly faster in 80A bottles. Three hundred thirty-eight of the 6,305 blood cultures evaluated in this study (5.4%) were judged likely to be contaminated. The percentages of probable contaminated cultures were as follows: 26.6% FAN and 80A; 42.3% FAN only; 31.1% 80A only (P < 0.05). Finally, the instrument false-positive rates for the two systems were 0.7% with FAN and 3.0% with 80A (P < 0.05). We conclude that while contamination rates were slightly higher with FAN than with 80A, use of FAN aerobic bottles in conjunction with the BacT/Alert system will yield significantly higher numbers of clinically significant blood culture isolates than 80A bottles and the ESP system. Furthermore, this enhanced detection is most conspicuous in patients receiving antimicrobial therapy at the time blood cultures are performed, probably due to the presence of an antimicrobial-absorbing material in FAN aerobic bottles.
Similar articles
-
Controlled evaluation of BacT/Alert standard aerobic and FAN aerobic blood culture bottles for detection of bacteremia and fungemia.J Clin Microbiol. 1995 Apr;33(4):978-81. doi: 10.1128/jcm.33.4.978-981.1995. J Clin Microbiol. 1995. PMID: 7790471 Free PMC article. Clinical Trial.
-
Controlled clinical laboratory comparison of BACTEC plus aerobic/F resin medium with BacT/Alert aerobic FAN medium for detection of bacteremia and fungemia.J Clin Microbiol. 1997 Jan;35(1):53-8. doi: 10.1128/jcm.35.1.53-58.1997. J Clin Microbiol. 1997. PMID: 8968880 Free PMC article.
-
Comparison of the BacT/Alert FAN aerobic and the Difco ESP 80A aerobic bottles for pediatric blood cultures.J Clin Microbiol. 1997 May;35(5):1166-71. doi: 10.1128/jcm.35.5.1166-1171.1997. J Clin Microbiol. 1997. PMID: 9114401 Free PMC article.
-
Update on detection of bacteremia and fungemia.Clin Microbiol Rev. 1997 Jul;10(3):444-65. doi: 10.1128/CMR.10.3.444. Clin Microbiol Rev. 1997. PMID: 9227861 Free PMC article. Review.
-
Blood culture contamination: persisting problems and partial progress.J Clin Microbiol. 2003 Jun;41(6):2275-8. doi: 10.1128/JCM.41.6.2275-2278.2003. J Clin Microbiol. 2003. PMID: 12791835 Free PMC article. Review. No abstract available.
Cited by
-
Initial concentration of Staphylococcus epidermidis in simulated pediatric blood cultures correlates with time to positive results with the automated, continuously monitored BACTEC blood culture system.J Clin Microbiol. 2002 Mar;40(3):898-901. doi: 10.1128/JCM.40.3.898-901.2002. J Clin Microbiol. 2002. PMID: 11880412 Free PMC article.
-
Performance of five agar media for recovery of fungi from isolator blood cultures.J Clin Microbiol. 2000 Oct;38(10):3827-9. doi: 10.1128/JCM.38.10.3827-3829.2000. J Clin Microbiol. 2000. PMID: 11015411 Free PMC article.
-
Apparent culture-negative prosthetic valve endocarditis caused by Peptostreptococcus magnus.J Clin Microbiol. 2000 Dec;38(12):4640-2. doi: 10.1128/JCM.38.12.4640-4642.2000. J Clin Microbiol. 2000. PMID: 11101611 Free PMC article.
-
Use of a panfungal PCR assay for detection of fungal pathogens in a commercial blood culture system.J Clin Microbiol. 2004 May;42(5):2292-3. doi: 10.1128/JCM.42.5.2292-2293.2004. J Clin Microbiol. 2004. PMID: 15131216 Free PMC article.
-
Rapid real-time nucleic Acid sequence-based amplification-molecular beacon platform to detect fungal and bacterial bloodstream infections.J Clin Microbiol. 2009 Jul;47(7):2067-78. doi: 10.1128/JCM.02230-08. Epub 2009 Apr 29. J Clin Microbiol. 2009. PMID: 19403758 Free PMC article.
References
-
- Doern G V, Barton A, Rao S. Abstracts of the 97th General Meeting of the American Society for Microbiology 1997. Washington, D.C: American Society for Microbiology; 1997. Comparison of the BacT/Alert aerobic FAN medium and Difco ESP aerobic medium as means for detecting bacteremia and fungemia, abstr. C-433; p. 195.
-
- Hollick G E, Edinger R, Martin B. Clinical comparison of the BACTEC 9000 standard anaerobic/F and lytic/F blood culture media. Diagn Microbiol Infect Dis. 1996;24:191–196. - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical