Electrocardiographically gated myocardial perfusion SPECT: technical principles and quality control considerations
- PMID: 9715987
- DOI: 10.1016/s1071-3581(98)90148-9
Electrocardiographically gated myocardial perfusion SPECT: technical principles and quality control considerations
Similar articles
-
Gated technetium-99m sestamibi for simultaneous assessment of stress myocardial perfusion, postexercise regional ventricular function and myocardial viability. Correlation with echocardiography and rest thallium-201 scintigraphy.J Am Coll Cardiol. 1994 Apr;23(5):1107-14. doi: 10.1016/0735-1097(94)90598-3. J Am Coll Cardiol. 1994. PMID: 8144776
-
Quantification of left ventricular function with thallium-201 and technetium-99m-sestamibi myocardial gated SPECT.J Nucl Med. 1997 Jun;38(6):958-61. J Nucl Med. 1997. PMID: 9189150
-
A comparison of Tl-201 stress-reinjection-prone SPECT and Tc-99m-sestamibi gated SPECT in the differentiation of inferior wall defects from artifacts.Nucl Med Commun. 2000 Aug;21(8):719-27. doi: 10.1097/00006231-200008000-00004. Nucl Med Commun. 2000. PMID: 11039454 Clinical Trial.
-
The diagnostic and prognostic value of ECG-gated SPECT myocardial perfusion imaging.J Nucl Med. 2004 May;45(5):912-21. J Nucl Med. 2004. PMID: 15136643 Review.
-
Artifacts in planar and SPECT myocardial perfusion imaging.Am J Card Imaging. 1992 Mar;6(1):42-57; discussion 58. Am J Card Imaging. 1992. PMID: 10147614 Review. No abstract available.
Cited by
-
Comparison between ECTb and QGS for assessment of left ventricular function from gated myocardial perfusion SPECT.J Nucl Cardiol. 2002 May-Jun;9(3):285-93. doi: 10.1067/mnc.2002.121449. J Nucl Cardiol. 2002. PMID: 12032476
-
Simultaneous assessment of cardiac perfusion and function using 5-dimensional imaging with Tc-99m teboroxime.J Nucl Cardiol. 2006 May-Jun;13(3):354-61. doi: 10.1016/j.nuclcard.2006.03.004. J Nucl Cardiol. 2006. PMID: 16750780
-
Reliability of myocardial perfusion gated SPECT for the reproducible evaluation of resting left ventricular functional parameters in long-term follow-up.Eur J Nucl Med Mol Imaging. 2010 Aug;37(9):1722-9. doi: 10.1007/s00259-010-1444-y. Eur J Nucl Med Mol Imaging. 2010. PMID: 20393711
-
Clinical impact of arrhythmias on gated SPECT cardiac myocardial perfusion and function assessment.J Nucl Cardiol. 2001 Jan-Feb;8(1):19-30. doi: 10.1067/mnc.2001.111087. J Nucl Cardiol. 2001. PMID: 11182706
-
Interassay reproducibility of myocardial perfusion gated SPECT in patients with atrial fibrillation.J Nucl Cardiol. 2010 Jun;17(3):450-8. doi: 10.1007/s12350-009-9186-6. Epub 2009 Dec 25. J Nucl Cardiol. 2010. PMID: 20035390