Abstract
Purpose: Our purpose was to evaluate intraaneurysmal blood velocity by using time-density curve analysis and digital subtraction angiography.
Methods: In 31 aneurysms, aneurysmal blood velocity was examined with digital subtraction angiography to determine mean transit time (MTF), peak density time (time to peak opacification) (PDT), and time to half-peak opacification (T1/2). Thirty frames per second were acquired, and the time-density curve was calculated. Regions of interest were drawn on the proximal parent artery, on the distal parent artery, and on the aneurysm itself.
Results: There was no significant difference in MTT of blood velocity in the proximal site on the parent artery, in the distal site on the parent artery, and in the aneurysm. Similarly, there was no significant difference in PDT in the parent artery, in the distal site on the parent artery, and in the aneurysm; nor was there a significant difference in T1/2 in the parent artery, in the distal site on the parent artery, and in the aneurysm; that is, intraaneurysmal blood velocity was similar to that in the parent artery. PDT and T1/2 of small aneurysms were faster than that of large aneurysms; that is, blood velocity of small aneurysms was faster than that of large aneurysms.
Conclusion: Intraaneurysmal blood velocity in small aneurysms is similar to that in the parent artery; consequently, the central stream probably reaches the aneurysmal wall. Intraaneurysmal blood velocity in large aneurysms appears to be somewhat slower than that in small aneurysms.
Comment in
-
Understanding the natural history of saccular aneurysms.AJNR Am J Neuroradiol. 1998 Aug;19(7):1183-4. AJNR Am J Neuroradiol. 1998. PMID: 9726448 Free PMC article. No abstract available.
Similar articles
-
Visualization of intraaneurysmal flow patterns with transluminal flow images of 3D MR angiograms in conjunction with aneurysmal configurations.AJNR Am J Neuroradiol. 2003 Aug;24(7):1436-45. AJNR Am J Neuroradiol. 2003. PMID: 12917142 Free PMC article.
-
CT detection of intracranial aneurysms in subarachnoid hemorrhage.AJR Am J Roentgenol. 1979 Apr;132(4):613-6. doi: 10.2214/ajr.132.4.613. AJR Am J Roentgenol. 1979. PMID: 106694
-
Quantitative flow measurement after placing a flow diverter for a distal internal carotid artery aneurysm.J Neurointerv Surg. 2017 Dec;9(12):1238-1242. doi: 10.1136/neurintsurg-2016-012730. Epub 2016 Dec 8. J Neurointerv Surg. 2017. PMID: 27932668
-
Clipping in Awake Surgery as End-Stage in a Complex Internal Carotid Artery Aneurysm After Failure of Multimodal Endovascular and Extracranial-Intracranial Bypass Treatment.J Stroke Cerebrovasc Dis. 2017 Jun;26(6):e114-e118. doi: 10.1016/j.jstrokecerebrovasdis.2017.03.028. Epub 2017 Apr 13. J Stroke Cerebrovasc Dis. 2017. PMID: 28416090
-
Intravascular stent and endovascular coil placement for a ruptured fusiform aneurysm of the basilar artery. Case report and review of the literature.J Neurosurg. 1997 Dec;87(6):944-9. doi: 10.3171/jns.1997.87.6.0944. J Neurosurg. 1997. PMID: 9384409 Review.
Cited by
-
Analysis of intra-aneurysmal flow for cerebral aneurysms with cerebral angiography.AJNR Am J Neuroradiol. 2012 Oct;33(9):1679-84. doi: 10.3174/ajnr.A3057. Epub 2012 May 10. AJNR Am J Neuroradiol. 2012. PMID: 22576897 Free PMC article.
-
Morphologic and hemodynamic changes after stent placement for experimental carotid aneurysm.Interv Neuroradiol. 2002 Jun 30;8(2):143-9. doi: 10.1177/159101990200800206. Epub 2004 Oct 20. Interv Neuroradiol. 2002. PMID: 20594523 Free PMC article.
-
Peritherapeutic Hemodynamic Changes of Carotid Stenting Evaluated with Quantitative DSA in Patients with Carotid Stenosis.AJNR Am J Neuroradiol. 2016 Oct;37(10):1883-1888. doi: 10.3174/ajnr.A4813. Epub 2016 May 12. AJNR Am J Neuroradiol. 2016. PMID: 27173363 Free PMC article.
-
Angiographic quantification of contrast medium washout from cerebral aneurysms after stent placement.AJNR Am J Neuroradiol. 2002 Aug;23(7):1214-21. AJNR Am J Neuroradiol. 2002. PMID: 12169482 Free PMC article.
-
Effect of Guglielmi detachable coils on intraaneurysmal flow: experimental study in canines.AJNR Am J Neuroradiol. 2002 Feb;23(2):288-94. AJNR Am J Neuroradiol. 2002. PMID: 11847057 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous