Unipolar or bipolar prosthesis for the displaced intracapsular hip fracture? An unanswered question
- PMID: 9728162
- DOI: 10.1097/00003086-199808000-00010
Unipolar or bipolar prosthesis for the displaced intracapsular hip fracture? An unanswered question
Abstract
Modular bipolar prostheses were developed to address the problems of loosening, cartilage wear, and protrusio which were seen with single unit endoprostheses. Modular unipolar prostheses address many of these problems and are significantly less expensive than the bipolar prosthesis. Recent data suggest that use of the modular unipolar prosthesis is indicated in elderly patients with low demands.
Similar articles
-
Unipolar or bipolar prosthesis for displaced intracapsular hip fracture in octogenarians: a randomised prospective study.J Bone Joint Surg Br. 1996 May;78(3):391-4. J Bone Joint Surg Br. 1996. PMID: 8636172 Clinical Trial.
-
Unipolar or bipolar prosthesis for displaced intracapsular hip fracture.J Bone Joint Surg Br. 1997 Jul;79(4):694-5. J Bone Joint Surg Br. 1997. PMID: 9250768 No abstract available.
-
Massive osteolysis due to failure of a unipolar endoprosthesis.J Arthroplasty. 2008 Dec;23(8):1240.e5-8. doi: 10.1016/j.arth.2007.10.024. Epub 2008 Apr 8. J Arthroplasty. 2008. PMID: 18534461
-
Dislocation after primary arthroplasty for subcapital fracture of the hip. Wide range of movement is a risk factor.J Bone Joint Surg Br. 1991 Jan;73(1):11-2. doi: 10.1302/0301-620X.73B1.1991741. J Bone Joint Surg Br. 1991. PMID: 1991741 Review.
-
Dissociation of bipolar hemiarthroplasty of the hip after dislocation. A report of five different cases and review of literature.Injury. 2006 Feb;37(2):162-8. doi: 10.1016/j.injury.2005.09.014. Epub 2006 Jan 18. Injury. 2006. PMID: 16420955 Review.
Cited by
-
Interventions for treating displaced intracapsular femoral neck fractures in the elderly: a Bayesian network meta-analysis of randomized controlled trials.Sci Rep. 2017 Oct 12;7(1):13103. doi: 10.1038/s41598-017-13377-1. Sci Rep. 2017. PMID: 29026135 Free PMC article.
-
A comparison between Austin-Moore and Corail prosthesis regarding intraoperative periprosthetic femur fractures in hip hemiarthroplasty.Sci Rep. 2022 Apr 15;12(1):6340. doi: 10.1038/s41598-022-10384-9. Sci Rep. 2022. PMID: 35428861 Free PMC article.
-
Bipolar versus monopolar hemiarthroplasty for displaced femur neck fractures: a meta-analysis study.Eur J Orthop Surg Traumatol. 2020 Apr;30(3):401-410. doi: 10.1007/s00590-019-02600-6. Epub 2019 Nov 26. Eur J Orthop Surg Traumatol. 2020. PMID: 31773262 Review.
-