Modification of the in vivo four-point loading model for studying mechanically induced bone adaptation
- PMID: 9737355
- DOI: 10.1016/s8756-3282(98)00090-8
Modification of the in vivo four-point loading model for studying mechanically induced bone adaptation
Abstract
We modified the noninvasive, in vivo technique for strain application in the tibiae of rats (Turner et al., Bone 12:73-79, 1991). The original model applies four-point bending to right tibiae via an open-loop, stepper-motor-driven spring linkage. Depending on the magnitude of applied load, the model produces new bone formation at periosteal (Ps) or endocortical surfaces (Ec.S). Due to the spring linkage, however, the range of frequencies at which loads can be applied is limited. The modified system replaces this design with an electromagnetic vibrator. A load transducer in series with the loading points allows calibration, the loaders' position to be adjusted, and cyclic loading completed under load control as a closed servo-loop. Two experiments were conducted to validate the modified system: (1) a strain gauge was applied to the lateral surface of the right tibia of 5 adult female rats and strains measured at applied loads from 10 to 60 N; and (2) the bone formation response was determined in 28 adult female Sprague-Dawley rats. Loading was applied as a haversine wave with a frequency of 2 Hz for 18 sec, every second day for 10 days. Peak bending loads were applied at 33, 40, 52, and 64 N, and a sham-loading group was included at 64 N. Strains in the tibiae were linear between 10 and 60 N, and the average peak strain at the Ps.S at 60 N was 2664 +/- 250 microstrain, consistent with the results of Turner's group. Lamellar bone formation was stimulated at the Ec.S by applied bending, but not by sham loading. Bending strains above a loading threshold of 40 N increased Ec lamellar bone formation rate, bone forming surface, and mineral apposition rate with a dose response similar to that reported by Turner et al. (J Bone Miner Res 9:87-97, 1994). We conclude that the modified loading system offers precision for applied loads of between 0 and 70 N, versatility in the selection of loading rates up to 20 Hz, and a reproducible bone formation response in the rat tibia. Adjustment of the loader also enables study of mechanical usage in murine tibia, an advantage with respect to the increasing variety of transgenic strains available in bone and mineral research.
Comment in
-
Effects of tissue viscoelasticity on mechanical loading models using rats.Bone. 1999 Dec;25(6):742. doi: 10.1016/s8756-3282(99)00233-1. Bone. 1999. PMID: 10593421 No abstract available.
Similar articles
-
Mechanical loading thresholds for lamellar and woven bone formation.J Bone Miner Res. 1994 Jan;9(1):87-97. doi: 10.1002/jbmr.5650090113. J Bone Miner Res. 1994. PMID: 8154314
-
Viscoelastic response of the rat loading model: implications for studies of strain-adaptive bone formation.Bone. 1999 Sep;25(3):379-82. doi: 10.1016/s8756-3282(99)00181-7. Bone. 1999. PMID: 10495144
-
Periosteal bone formation stimulated by externally induced bending strains.J Bone Miner Res. 1994 Aug;9(8):1143-52. doi: 10.1002/jbmr.5650090803. J Bone Miner Res. 1994. PMID: 7976496
-
Skeletal adaptations to mechanical usage: results from tibial loading studies in rats.Bone. 1995 Oct;17(4 Suppl):197S-205S. doi: 10.1016/8756-3282(95)00292-l. Bone. 1995. PMID: 8579917 Review.
-
The Contribution of Experimental in vivo Models to Understanding the Mechanisms of Adaptation to Mechanical Loading in Bone.Front Endocrinol (Lausanne). 2014 Oct 1;5:154. doi: 10.3389/fendo.2014.00154. eCollection 2014. Front Endocrinol (Lausanne). 2014. PMID: 25324829 Free PMC article. Review.
Cited by
-
Osteocyte expression of caspase-3, COX-2, IL-6 and sclerostin are spatially and temporally associated following stress fracture initiation.Bonekey Rep. 2014 Sep 3;3:571. doi: 10.1038/bonekey.2014.66. eCollection 2014. Bonekey Rep. 2014. PMID: 25228984 Free PMC article.
-
Increased expression of matrix extracellular phosphoglycoprotein (MEPE) in cortical bone of the rat tibia after mechanical loading: identification by oligonucleotide microarray.PLoS One. 2013 Nov 8;8(11):e79672. doi: 10.1371/journal.pone.0079672. eCollection 2013. PLoS One. 2013. PMID: 24255709 Free PMC article.
-
Differences in trabecular bone of leptin-deficient ob/ob mice in response to biomechanical loading.Int J Biol Sci. 2008 Jun 15;4(3):169-75. doi: 10.7150/ijbs.4.169. Int J Biol Sci. 2008. PMID: 18566694 Free PMC article.
-
Design and analysis of a novel mechanical loading machine for dynamic in vivo axial loading.Rev Sci Instrum. 2012 Feb;83(2):025113. doi: 10.1063/1.3687781. Rev Sci Instrum. 2012. PMID: 22380131 Free PMC article.
-
32 wk old C3H/HeJ mice actively respond to mechanical loading.Bone. 2008 Apr;42(4):653-9. doi: 10.1016/j.bone.2007.12.222. Epub 2008 Jan 15. Bone. 2008. PMID: 18280231 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources