In situ calibration of miniature sensors implanted into the anterior cruciate ligament part I: strain measurements
- PMID: 9747787
- DOI: 10.1002/jor.1100160410
In situ calibration of miniature sensors implanted into the anterior cruciate ligament part I: strain measurements
Abstract
The goals of this study were to (a) evaluate the differential variable reluctance transducer as an instrument for measuring tissue strain in the anteromedial band of the anterior cruciate ligament, (b) develop a series of calibration curves (for simple states of knee loading) from which resultant force in the ligament could be estimated from measured strain levels in the anteromedial band of the ligament, and (c) study the effects of knee flexion angle and mode of applied loading on output from the transducer. Thirteen fresh-frozen cadaveric knee specimens underwent mechanical isolation of a bone cap containing the tibial insertion of the anterior cruciate ligament and attachment of a load cell to measure resultant force in the ligament. The transducer (with barbed prongs) was inserted into the anteromedial band of the anterior cruciate ligament to record local elongation of the instrumented fibers as resultant force was generated in the ligament. A series of calibration curves (anteromedial bundle strain versus resultant force in the anterior cruciate ligament) were determined at selected knee flexion angles as external loads were applied to the knee. During passive knee extension, strain readings did not always follow the pattern of resultant force in the ligament; erratic strain readings were often measured beyond 20 degrees of flexion, where the anteromedial band was slack. For anterior tibial loading, the anteromedial band was a more active contributor to resultant ligament force beyond 45 degrees of flexion and was less active near full extension; mean resultant forces in the range of 150-200 N produced strain levels on the order of 3-4%. The anteromedial band was also active during application of internal tibial torque; mean resultant forces on the order of 180-220 N produced strains on the order of 2%. Resultant forces generated by varus moment were relatively low, and the anteromedial band was not always strained. Mean coefficients of variation for resultant force in the ligament (five repeated measurements) ranged between 0.038 and 0.111. Mean coefficients of variation for five repeated placements of the strain transducer in the same site ranged from 0.209 to 0.342. Insertion and removal of this transducer at the anteromedial band produced observable damage to the ligament. In our study, repeatable measurements were possible only if both prongs of the transducer were sutured to the ligament fibers.
Similar articles
-
In situ calibration of miniature sensors implanted into the anterior cruciate ligament part II: force probe measurements.J Orthop Res. 1998 Jul;16(4):464-71. doi: 10.1002/jor.1100160411. J Orthop Res. 1998. PMID: 9747788
-
In situ forces in the anterior cruciate ligament and its bundles in response to anterior tibial loads.J Orthop Res. 1997 Mar;15(2):285-93. doi: 10.1002/jor.1100150219. J Orthop Res. 1997. PMID: 9167633
-
Effects of knee flexion angles for graft fixation on force distribution in double-bundle anterior cruciate ligament grafts.Am J Sports Med. 2006 Apr;34(4):577-85. doi: 10.1177/0363546505281814. Epub 2005 Nov 10. Am J Sports Med. 2006. PMID: 16282574
-
On the interpretation of our anterior cruciate ligament data.Clin Orthop Relat Res. 1985 Jun;(196):26-34. Clin Orthop Relat Res. 1985. PMID: 3888470 Review.
-
Analysis and simulation of mechanical loads on the human musculoskeletal system: a methodological overview.Exerc Sport Sci Rev. 1994;22:23-51. Exerc Sport Sci Rev. 1994. PMID: 7925545 Review.
Cited by
-
Effect of increased quadriceps tensile stiffness on peak anterior cruciate ligament strain during a simulated pivot landing.J Orthop Res. 2014 Mar;32(3):423-30. doi: 10.1002/jor.22531. Epub 2013 Dec 2. J Orthop Res. 2014. PMID: 24302388 Free PMC article.
-
The effects of modified posterior tibial slope on anterior cruciate ligament strain and knee kinematics: a human cadaveric study.J Knee Surg. 2008 Jul;21(3):205-11. doi: 10.1055/s-0030-1247820. J Knee Surg. 2008. PMID: 18686482 Free PMC article.
-
Optical Measurement of Ligament Strain: Opportunities and Limitations for Intraoperative Application.Sensors (Basel). 2023 Aug 28;23(17):7487. doi: 10.3390/s23177487. Sensors (Basel). 2023. PMID: 37687943 Free PMC article. Review.
-
Size and Shape of the Human Anterior Cruciate Ligament and the Impact of Sex and Skeletal Growth: A Systematic Review.JBJS Rev. 2019 Jun;7(6):e8. doi: 10.2106/JBJS.RVW.18.00145. JBJS Rev. 2019. PMID: 31246862 Free PMC article.
-
Experimental mechanical strain measurement of tissues.PeerJ. 2019 Mar 7;7:e6545. doi: 10.7717/peerj.6545. eCollection 2019. PeerJ. 2019. PMID: 30867989 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous