Serial magnetization transfer imaging to characterize the early evolution of new MS lesions
- PMID: 9748023
- DOI: 10.1212/wnl.51.3.758
Serial magnetization transfer imaging to characterize the early evolution of new MS lesions
Abstract
Objective: To explore the temporal relation of demyelination and blood-brain barrier breakdown during new lesion formation.
Background: Conventional MRI appears sensitive for detecting changes due to MS, but may be limited by poor pathologic specificity. By indirectly assessing protons bound to rigid macromolecules, magnetization transfer (MT) imaging may provide information relating to tissue structure and, by inference, myelin integrity.
Methods: Gadolinium contrast-enhanced MRI and MT imaging were performed at weekly intervals for 3 months in three patients with MS. For each enhancing lesion, the largest corresponding area of proton density hyperintensity seen during the study was outlined and magnetization transfer ratio (MTR) calculated at each time point from coregistered calculated MTR images. Lesions greater than 20 mm2, not affected by partial volume effects, and first enhancing after the baseline study were analyzed. Two-dimensional registration software allowed accurate evaluation of MTR in regions both before and after the initial appearance of MS lesions.
Results: Mean lesion MTR decreased significantly during the first week of enhancement (29.6 percent units [pu] immediately pre-enhancement versus 28.2 pu at first documented stage of enhancement). No significant MTR reduction was noted before this.
Conclusion: The lack of observable change in MTR before the first detectable gadolinium enhancement within MS lesions suggests that blood-brain barrier disruption is closely related to, but not preceded by, demyelination.
Comment in
-
Serial magnetization transfer imaging to characterize the early evolution of new MS lesions.Neurology. 1999 May 12;52(8):1717. doi: 10.1212/wnl.52.8.1717. Neurology. 1999. PMID: 10331713 No abstract available.
Similar articles
-
Magnetization transfer effects in MR-detected multiple sclerosis lesions: comparison with gadolinium-enhanced spin-echo images and nonenhanced T1-weighted images.AJNR Am J Neuroradiol. 1995 Jan;16(1):69-77. AJNR Am J Neuroradiol. 1995. PMID: 7900604 Free PMC article.
-
Magnetization transfer changes in the normal appearing white matter precede the appearance of enhancing lesions in patients with multiple sclerosis.Ann Neurol. 1998 Jun;43(6):809-14. doi: 10.1002/ana.410430616. Ann Neurol. 1998. PMID: 9629851
-
Magnetization transfer ratios in multiple sclerosis lesions enhancing after different doses of gadolinium.Neurology. 1998 May;50(5):1289-93. doi: 10.1212/wnl.50.5.1289. Neurology. 1998. PMID: 9595976 Clinical Trial.
-
The role of magnetic resonance techniques in understanding and managing multiple sclerosis.Brain. 1998 Jan;121 ( Pt 1):3-24. doi: 10.1093/brain/121.1.3. Brain. 1998. PMID: 9549485 Review.
-
Characterization of tissue damage in multiple sclerosis by nuclear magnetic resonance.Philos Trans R Soc Lond B Biol Sci. 1999 Oct 29;354(1390):1675-86. doi: 10.1098/rstb.1999.0511. Philos Trans R Soc Lond B Biol Sci. 1999. PMID: 10603619 Free PMC article. Review.
Cited by
-
High-resolution magnetization transfer MRI in patients with cervical spondylotic myelopathy.J Clin Neurosci. 2018 May;51:57-61. doi: 10.1016/j.jocn.2018.02.023. Epub 2018 Mar 9. J Clin Neurosci. 2018. PMID: 29530383 Free PMC article.
-
Imaging of multiple sclerosis: role in neurotherapeutics.NeuroRx. 2005 Apr;2(2):277-303. doi: 10.1602/neurorx.2.2.277. NeuroRx. 2005. PMID: 15897951 Free PMC article. Review.
-
Advancements in Imaging Technology: Do They (or Will They) Equate to Advancements in Our Knowledge of Recovery in Whiplash?J Orthop Sports Phys Ther. 2016 Oct;46(10):862-873. doi: 10.2519/jospt.2016.6735. J Orthop Sports Phys Ther. 2016. PMID: 27690836 Free PMC article.
-
Increased diffusivity in acute multiple sclerosis lesions predicts risk of black hole.Neurology. 2010 May 25;74(21):1694-701. doi: 10.1212/WNL.0b013e3181e042c4. Neurology. 2010. PMID: 20498437 Free PMC article.
-
A standardised method for measuring magnetisation transfer ratio on MR imagers from different manufacturers--the EuroMT sequence.MAGMA. 2005 May;18(2):76-80. doi: 10.1007/s10334-004-0095-z. Epub 2005 Mar 22. MAGMA. 2005. PMID: 15785944 Clinical Trial.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical