Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1998 Sep-Oct;9(5):766-73.
doi: 10.1016/s1051-0443(98)70389-6.

Single institution prospective evaluation of the over-the-wire Greenfield vena caval filter

Affiliations

Single institution prospective evaluation of the over-the-wire Greenfield vena caval filter

S P Johnson et al. J Vasc Interv Radiol. 1998 Sep-Oct.

Abstract

Purpose: To assess the technical and clinical success of the over-the-wire (OTW) Greenfield inferior vena caval (IVC) filter.

Materials and methods: Prospective evaluation of the OTW Greenfield filter in 47 patients was performed during the course of 18 months. Technical success and deployment problems were documented. Caval perforation, leg asymmetry, and tilt were evaluated with a postprocedure, noncontrast computed tomographic (CT) scan. Follow-up was performed at 6- and 12-month intervals after the procedure and included a clinical history, chart review, and magnetic resonance (MR) imaging examination of the IVC.

Results: Ninety-one percent of filters were placed without technical difficulties and 100% were successfully deployed. Technical difficulties included sheath kinking prior to deployment (n = 3), initial incomplete filter opening (n = 1), and wire entrapment within the filter (n = 1). Of 38 patients evaluated with CT, there was no case of caval perforation. Twenty-one patients (55%) demonstrated tilt and 14 (37%) had leg asymmetry. Tilting occurred more frequently when the filter was placed from a femoral approach (51%) than from a jugular approach (12%). Of patients with leg asymmetry, the vena cava was narrow in anteroposterior (AP) dimension in five (36%). Of 13 deaths, none were attributed to pulmonary embolism. One patient (2%) had a recurrent pulmonary embolus. Two of 16 patients (12%) with MR imaging follow-up had documented IVC thrombosis.

Conclusions: The OTW Greenfield filter has an effective delivery system, with few difficulties encountered during deployment. Filter tilt and leg asymmetry are common. The etiology of leg asymmetry is likely multifactorial but is often associated with a cava with a small AP diameter. Because OTW deployment appears to offer no benefit in centering the filter, the authors have elected to remove the wire prior to filter deployment to avoid possible entanglement. MR imaging follow-up reveals an acceptable incidence of IVC thrombosis.

PubMed Disclaimer

Substances

LinkOut - more resources