Abstract
Objectives: The purpose of this study was to assess the efficacy of attenuation-corrected (AC) technetium-99m (99mTc)-tetrofosmin single-photon emission computed tomography (SPECT) in detecting viable myocardium compared to 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET).
Background: The role of 99mTc-labeled perfusion tracers in the assessment of myocardial viability remains controversial. Attenuation artifacts affect the diagnostic accuracy of SPECT images.
Methods: Twenty-four patients with coronary artery disease (mean left ventricular ejection fraction 30%) underwent resting 99mTc-tetrofosmin SPECT and FDG PET imaging. Both AC and non-attenuation-corrected (NC) SPECT images were generated.
Results: Using a 50% threshold for viability by FDG PET, the percentage of concordant segments of viability between 99mTc-tetrofosmin and FDG on the patient basis increased from 79.8%+/-14.0% (mean+/-SD) on the NC images to 90.8%+/-10.6% on the AC images (p=0.002). The percentage of 99mTc-tetrofosmin defect segments within PET-viable segments, an estimate for the degree of underestimation of viability, decreased from 19.8%+/-15.2% on the NC images to 9.7%+/-12.6% on the AC images (p=0.01). Similar results were obtained when a 60% threshold was used to define viability by FDG PET. When the anterior-lateral and inferior-septal regions were separately analyzed, the effect of attenuation correction was significant only in the inferior-septal region.
Conclusions: The results indicate that AC 99mTc-tetrofosmin SPECT improves the detection of viable myocardium mainly by decreasing the underestimation of viability particularly in the inferior-septal region, although some underestimation/overestimation of viability may still occur even with attenuation correction.
Similar articles
-
Comparison of nitrate augmented Tc-99m tetrofosmin gated SPECT imaging with FDG PET imaging for the assessment of myocardial viability in patients with severe left ventricular dysfunction.J Nucl Cardiol. 2012 Dec;19(6):1176-81. doi: 10.1007/s12350-012-9607-9. Epub 2012 Aug 8. J Nucl Cardiol. 2012. PMID: 22872319
-
Diagnosis of myocardial viability by dual-head coincidence gamma camera fluorine-18 fluorodeoxyglucose positron emission tomography with and without non-uniform attenuation correction.Eur J Nucl Med. 2000 Oct;27(10):1501-8. doi: 10.1007/s002590000316. Eur J Nucl Med. 2000. PMID: 11083539
-
Baseline/post-nitrate Tc-99m tetrofosmin mismatch for the assessment of myocardial viability in patients with severe left ventricular dysfunction: comparison with baseline Tc-99m tetrofosmin scintigraphy/FDG PET imaging.J Nucl Cardiol. 2004 Mar-Apr;11(2):142-51. doi: 10.1016/j.nuclcard.2003.12.011. J Nucl Cardiol. 2004. PMID: 15052245 Clinical Trial.
-
Are technetium-99m-labeled myocardial perfusion agents adequate for detection of myocardial viability?Clin Cardiol. 1998 Apr;21(4):235-42. doi: 10.1002/clc.4960210402. Clin Cardiol. 1998. PMID: 9562932 Free PMC article. Review.
-
18-Fluorodeoxyglucose imaging with positron emission tomography and single photon emission computed tomography: cardiac applications.Semin Nucl Med. 2000 Oct;30(4):281-98. doi: 10.1053/snuc.2000.9543. Semin Nucl Med. 2000. PMID: 11105929 Review.
Cited by
-
Prevalence of myocardial viability assessed by single photon emission computed tomography in patients with chronic ischaemic left ventricular dysfunction.Heart. 2002 Aug;88(2):125-30. doi: 10.1136/heart.88.2.125. Heart. 2002. PMID: 12117829 Free PMC article.
-
Reversible congestive heart failure caused by myocardial hibernation.Tex Heart Inst J. 1999;26(1):19-27. Tex Heart Inst J. 1999. PMID: 10217467 Free PMC article. Review.
-
Electrocardiographic-gated dual-isotope simultaneous acquisition SPECT using 18F-FDG and 99mTc-sestamibi to assess myocardial viability and function in a single study.Eur J Nucl Med Mol Imaging. 2005 Feb;32(2):195-202. doi: 10.1007/s00259-004-1668-9. Epub 2004 Sep 21. Eur J Nucl Med Mol Imaging. 2005. PMID: 15449050 Clinical Trial.
-
Comparison of nitrate augmented Tc-99m tetrofosmin gated SPECT imaging with FDG PET imaging for the assessment of myocardial viability in patients with severe left ventricular dysfunction.J Nucl Cardiol. 2012 Dec;19(6):1176-81. doi: 10.1007/s12350-012-9607-9. Epub 2012 Aug 8. J Nucl Cardiol. 2012. PMID: 22872319
-
Improved identification of viable myocardium using second harmonic imaging during dobutamine stress echocardiography.Heart. 2001 Dec;86(6):672-8. doi: 10.1136/heart.86.6.672. Heart. 2001. PMID: 11711466 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources