Comparative Study
. 1998 Nov;36(11):3273-7.
doi: 10.1128/JCM.36.11.3273-3277.1998.

Use of the BacT/Alert blood culture system for culture of sterile body fluids other than blood

Affiliations
Comparative Study

Use of the BacT/Alert blood culture system for culture of sterile body fluids other than blood

P Bourbeau et al. J Clin Microbiol. 1998 Nov.

Abstract

Studies have demonstrated that large-volume culture methods for sterile body fluids other than blood increase recovery compared to traditional plated-medium methods. BacT/Alert is a fully automated blood culture system for detecting bacteremia and fungemia. In this study, we compared culture in BacT/Alert standard aerobic and anaerobic bottles, BacT/Alert FAN aerobic and FAN anaerobic bottles, and culture on routine media for six specimen types, i.e., continuous ambulatory peritoneal dialysate (CAPD), peritoneal, amniotic, pericardial, synovial, and pleural fluids. Specimen volumes were divided equally among the three arms of the study. A total of 1,157 specimens were tested, with 227 significant isolates recovered from 193 specimens. Recovery by method was as follows: standard bottles, 186 of 227 (82%); FAN bottles, 217 of 227 (96%); and routine culture, 184 of 227 (81%). The FAN bottles recovered significantly more gram-positive cocci (P < 0.001), Staphylococcus aureus (P = 0.003), coagulase-negative staphylococci (P = 0.008), gram-negative bacilli (P < 0.001), Enterobacteriaceae (P = 0.005), and total organisms (P < 0.001) than the routine culture. There were no significant differences in recovery between the standard bottles and the routine culture. The FAN aerobic bottle recovered significantly more gram-positive cocci (P < 0.001), S. aureus isolates (P < 0.001), coagulase-negative staphyococci (P = 0.003), and total organisms (P < 0.001) than the standard aerobic bottle, while the FAN anaerobic bottle recovered significantly more gram-positive cocci (P < 0.001), S. aureus isolates (P < 0.001), Enterobacteriaceae (P = 0.03), and total organisms (P < 0.001) than the standard anaerobic bottle. For specific specimen types, significantly more isolates were recovered from the FAN bottles compared to the routine culture for synovial (P < 0.001) and CAPD (P = 0.004) fluids. Overall, the FAN bottles were superior in performance to both the standard bottles and the routine culture for detection of microorganisms from the types of sterile body fluids included in this study.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Alfa M J, Degagne P, Olson N, Harding G K M. Improved detection of bacterial growth in continuous ambulatory peritoneal dialysis effluent by the use of BacT/Alert FAN bottles. J Clin Microbiol. 1997;35:862–866. - PMC - PubMed
    1. Ballou D, Goldsberry C, Miller R, Neumon D, O’Brien E, Oelsner M, Pettegrew J, Urbassik L, Salyer J. Abstracts of the 93rd General Meeting of the American Society for Microbiology 1993. Washington, D.C: American Society for Microbiology; 1993. Improved recovery of microorganisms from continuous ambulatory peritoneal dialysate by using BacT/Alert blood culture bottles (Organon Teknika), abstr. C-389; p. 515.
    1. Bobadilla M, Sifuentes J, Garcia-Tsao G. Improved method for the bacteriological diagnosis of spontaneous bacterial peritonitis. J Clin Microbiol. 1989;27:2145–2147. - PMC - PubMed
    1. Elston H R, Wang M, Philip A. Evaluation of Isolator system and large-volume centrifugation method for culturing body fluids. J Clin Microbiol. 1990;28:124–125. - PMC - PubMed
    1. Fuller D D, Davis T E, Kibsey P C, Rosmus L, Ayers L W, Ott M, Saubolle M A, Sewell D L. Comparison of BACTEC Plus 26 and 27 media with and without fastidious organism supplement with conventional methods for culture of sterile body fluids. J Clin Microbiol. 1994;32:1488–1491. - PMC - PubMed

Publication types

MeSH terms