Periotron 8000: calibration characteristics and reliability
Abstract
The Periotron is an instrument designed to quantify submicrolitre volumes of fluid sampled on a filter paper strip. To date 3 models have been manufactured: the Periotron 600 (1976), the Periotron 6000 (1983) and more recently the Periotron 8000 (1995). This paper investigated for the first time the calibration characteristics and reliability of the Periotron 8000. The fluids under investigation were: de-ionised water, human serum, fetal bovine serum and an ultrafiltrate of fetal bovine serum. Quantitative analysis was studied by recording a series of Periotron readings over a volume range of 0-1.0 microliters for each fluid. The average of 5 Periotron values for each particular fluid was then plotted versus the respective fluid volume. Qualitative changes in fluid composition versus Periotron Scores were also analysed. Volume conversion for Periotron scores using both Periotron MLCONVRT software and a best fit equation selected from TableCurve 2D software compared well. The results of this study revealed that: 1) differences in calibration fluid composition (e.g. protein content) are reflected in the Periotron scores; 2) positioning of filter paper strip between the jaws of the Periotron should be standardised, 3) calibration of the Periotron 8000 seems to be consistent over a 1-wk interval.
Similar articles
-
Calibration and reliability of the Periotron 6000 for individual gingival crevicular fluid samples.J Periodontal Res. 1995 Jan;30(1):73-9. doi: 10.1111/j.1600-0765.1995.tb01255.x. J Periodontal Res. 1995. PMID: 7722849
-
Reliability of standardized narrow strips in the Periotron.J Periodontol. 1985 Nov;56(11):686-9. doi: 10.1902/jop.1985.56.11.686. J Periodontol. 1985. PMID: 3903103
-
Calibration of the Periotron 8000 and 6000 by polynomial regression.J Periodontal Res. 1999 Feb;34(2):79-86. doi: 10.1111/j.1600-0765.1999.tb02226.x. J Periodontal Res. 1999. PMID: 10207836
-
The evaluation of the periotron.J Periodontol. 1979 Aug;50(8):424-6. doi: 10.1902/jop.1979.50.8.424. J Periodontol. 1979. PMID: 383944
-
The gingival crevicular fluid meter. Its use and abuse.N Y State Dent J. 1987 Dec;53(10):30-2. N Y State Dent J. 1987. PMID: 3320831 Review. No abstract available.
Cited by
-
Wound samples: moving towards a standardised method of collection and analysis.Int Wound J. 2016 Oct;13(5):880-91. doi: 10.1111/iwj.12399. Epub 2015 Jan 11. Int Wound J. 2016. PMID: 25581688 Free PMC article. Review.
-
Safety of oral mucosal punch biopsy and other oral biospecimen collections in clinical research.Oral Surg Oral Med Oral Pathol Oral Radiol. 2025 Mar;139(3):344-351. doi: 10.1016/j.oooo.2024.10.084. Epub 2024 Oct 30. Oral Surg Oral Med Oral Pathol Oral Radiol. 2025. PMID: 39532605
-
Optimization of buffer solutions to analyze inflammatory cytokines in gingival crevicular fluid by multiplex flow cytometry.Med Oral Patol Oral Cir Bucal. 2015 Jan 1;20(1):e13-6. doi: 10.4317/medoral.19852. Med Oral Patol Oral Cir Bucal. 2015. PMID: 24880451 Free PMC article.
-
Comparative volumetric and clinical evaluation of peri-implant sulcular fluid and gingival crevicular fluid.J Periodontal Implant Sci. 2013 Oct;43(5):233-42. doi: 10.5051/jpis.2013.43.5.233. Epub 2013 Oct 29. J Periodontal Implant Sci. 2013. PMID: 24236246 Free PMC article.
-
Influence of breathing route on upper airway lining liquid surface tension in humans.J Physiol. 2006 Aug 1;574(Pt 3):859-66. doi: 10.1113/jphysiol.2005.102129. Epub 2006 May 11. J Physiol. 2006. PMID: 16690717 Free PMC article. Clinical Trial.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources