Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1998 Oct;24(10):1320-5.
doi: 10.1016/s0886-3350(98)80222-8.

Correlation of intraocular pressure and central corneal thickness in normal myopic eyes and after laser in situ keratomileusis

Affiliations

Correlation of intraocular pressure and central corneal thickness in normal myopic eyes and after laser in situ keratomileusis

B Emara et al. J Cataract Refract Surg. 1998 Oct.

Abstract

Purpose: To determine the relationship of intraocular pressure (IOP) and central corneal thickness (CCT) in normal myopic eyes and after laser in situ keratomileusis (LASIK).

Setting: TLC The Windsor Laser Center, Windsor, Ontario, Canada.

Methods: Intraocular pressure measured by Goldmann applanation tonometry and CCT by ultrasonic pachymetry were determined in a group of untreated corneas of 120 patients (203 eyes) and in 50 patients (85 eyes) pre- and post-LASIK. Statistical analyses were performed with the Pearson correlation coefficient and paired Student t test.

Results: In the untreated group of 288 eyes, mean CCT was 544.0 microns +/- 37.3 (SD) (range 461 to 664 microns) and mean IOP, 15.6 +/- 2.7 mm Hg (range 10 to 24 mm Hg). The correlation between IOP and CCT in this group was highly significant (r = 0.44; P < .0001). The slope was 0.032 mm Hg/micron of CCT or an approximate decrease of 1 mm Hg, for a reduction in CCT of 31.3 microns. In the post-LASIK group, mean CCT dropped approximately 73.0 microns to 479.5 +/- 41.2 microns (range 408 to 503 microns) and IOP dropped to a mean of 13.6 +/- 3.3 mm Hg (range 7 to 22 mm Hg). A significant correlation was found between IOP and CCT after LASIK (r = 0.33; P < .002). The difference between the mean pre- and post-LASIK measurements of applanation IOP was 2.5 mm Hg, which was significant (P < .0001). The post-LASIK slope was 0.027 mm Hg/micron, or a decrease of 1.0 mm Hg per 37.8 microns reduction in CCT.

Conclusion: Central corneal thickness is an important variable in the evaluation of applanation IOP and should be included in the assessment of any case of potential glaucoma or ocular hypertension, particularly in eyes with previous photoablative refractive surgery.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources