Correlation of intraocular pressure and central corneal thickness in normal myopic eyes and after laser in situ keratomileusis
- PMID: 9795845
- DOI: 10.1016/s0886-3350(98)80222-8
Correlation of intraocular pressure and central corneal thickness in normal myopic eyes and after laser in situ keratomileusis
Abstract
Purpose: To determine the relationship of intraocular pressure (IOP) and central corneal thickness (CCT) in normal myopic eyes and after laser in situ keratomileusis (LASIK).
Setting: TLC The Windsor Laser Center, Windsor, Ontario, Canada.
Methods: Intraocular pressure measured by Goldmann applanation tonometry and CCT by ultrasonic pachymetry were determined in a group of untreated corneas of 120 patients (203 eyes) and in 50 patients (85 eyes) pre- and post-LASIK. Statistical analyses were performed with the Pearson correlation coefficient and paired Student t test.
Results: In the untreated group of 288 eyes, mean CCT was 544.0 microns +/- 37.3 (SD) (range 461 to 664 microns) and mean IOP, 15.6 +/- 2.7 mm Hg (range 10 to 24 mm Hg). The correlation between IOP and CCT in this group was highly significant (r = 0.44; P < .0001). The slope was 0.032 mm Hg/micron of CCT or an approximate decrease of 1 mm Hg, for a reduction in CCT of 31.3 microns. In the post-LASIK group, mean CCT dropped approximately 73.0 microns to 479.5 +/- 41.2 microns (range 408 to 503 microns) and IOP dropped to a mean of 13.6 +/- 3.3 mm Hg (range 7 to 22 mm Hg). A significant correlation was found between IOP and CCT after LASIK (r = 0.33; P < .002). The difference between the mean pre- and post-LASIK measurements of applanation IOP was 2.5 mm Hg, which was significant (P < .0001). The post-LASIK slope was 0.027 mm Hg/micron, or a decrease of 1.0 mm Hg per 37.8 microns reduction in CCT.
Conclusion: Central corneal thickness is an important variable in the evaluation of applanation IOP and should be included in the assessment of any case of potential glaucoma or ocular hypertension, particularly in eyes with previous photoablative refractive surgery.
Similar articles
-
Central corneal thickness and intraocular pressure relationship in eyes with and without previous LASIK: comparison of Goldmann applanation tonometer with pneumatonometer.Eur J Ophthalmol. 2005 Jan-Feb;15(1):81-8. Eur J Ophthalmol. 2005. PMID: 15751244
-
Changes in biomechanical properties of the cornea and intraocular pressure after myopic laser in situ keratomileusis using a femtosecond laser for flap creation determined using ocular response analyzer and Goldmann applanation tonometry.J Glaucoma. 2015 Mar;24(3):195-201. doi: 10.1097/IJG.0b013e31829da1ec. J Glaucoma. 2015. PMID: 23807345
-
Effect of mild to moderate myopic correction by laser-assisted in situ keratomileusis on intraocular pressure measurements with goldmann applanation tonometer, tono-pen, and pneumatonometer.J Glaucoma. 2002 Dec;11(6):493-6. doi: 10.1097/00061198-200212000-00007. J Glaucoma. 2002. PMID: 12483093
-
Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach.Surv Ophthalmol. 2000 Mar-Apr;44(5):367-408. doi: 10.1016/s0039-6257(00)00110-7. Surv Ophthalmol. 2000. PMID: 10734239 Review.
-
The corneal thickness and intraocular pressure story: where are we now?Clin Exp Ophthalmol. 2002 Oct;30(5):334-7. doi: 10.1046/j.1442-9071.2002.00551.x. Clin Exp Ophthalmol. 2002. PMID: 12213156 Review.
Cited by
-
Reliability of Intraocular Pressure Measurement by Goldmann Applanation Tonometry After Refractive Surgery: A Review of Different Correction Formulas.Clin Ophthalmol. 2020 Sep 24;14:2783-2788. doi: 10.2147/OPTH.S263856. eCollection 2020. Clin Ophthalmol. 2020. PMID: 33061262 Free PMC article. Review.
-
Comparison of different intraocular pressure measurement techniques in normal eyes, post surface and post lamellar refractive surgery.Clin Ophthalmol. 2013;7:71-9. doi: 10.2147/OPTH.S37978. Epub 2013 Jan 8. Clin Ophthalmol. 2013. PMID: 23326186 Free PMC article.
-
Dynamic contour tonometry versus Goldmann applanation tonometry: a comparative study.Graefes Arch Clin Exp Ophthalmol. 2005 Aug;243(8):763-7. doi: 10.1007/s00417-005-1124-y. Epub 2005 Mar 9. Graefes Arch Clin Exp Ophthalmol. 2005. PMID: 15756572
-
Effect of tetracaine on intraocular pressure in normal and hypertensive rabbit eyes.J Ophthalmic Vis Res. 2012 Jan;7(1):29-33. J Ophthalmic Vis Res. 2012. PMID: 22737384 Free PMC article.
-
A new rebound tonometer for home monitoring of intraocular pressure.Graefes Arch Clin Exp Ophthalmol. 2011 Nov;249(11):1713-9. doi: 10.1007/s00417-011-1785-7. Epub 2011 Aug 14. Graefes Arch Clin Exp Ophthalmol. 2011. PMID: 21842435 Clinical Trial.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources