Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1998 Nov;171(5):1259-63.
doi: 10.2214/ajr.171.5.9798857.

Sonographic guidance when using the right internal jugular vein for central vein access

Affiliations

Sonographic guidance when using the right internal jugular vein for central vein access

J G Caridi et al. AJR Am J Roentgenol. 1998 Nov.

Abstract

Objective: The intent of this study was to substantiate the advantages of the use of sonographic guidance for central venous access via the right internal jugular vein.

Subjects and methods: Eighty sequential patients requiring central vein access were examined with a hand-held sonography transducer to determine the size, patency, and location of the right internal jugular vein before puncture. Access to the right internal jugular vein was subsequently performed, under sterile conditions, using sonographic guidance. Periprocedural complications were prospectively recorded. Subsequently, we compared our findings with published reports of complications when visible and palpable anatomic landmarks were used for guidance during cannulation of the internal jugular vein.

Results: Among these 80 patients, the anatomy of the right internal jugular vein was typical in only 57 (71%). In another 13 patients (16%), sonography showed a medial position of the right internal jugular vein, anterior to the common carotid artery. In three other patients (4%), the right internal jugular vein was positioned laterally by more than 1 cm. In the remaining seven patients (9%), the vein was thrombosed. Its diameter, measured without use of the Valsalva maneuver, also varied, measuring 0.5-2.0 cm. Cannulation was achieved in all 73 patients with a patent right internal jugular vein. One puncture was required in 68 patients (93%); two punctures in three other patients (4%); and three punctures in the remaining two patients (3%). In no case was the common carotid artery inadvertently punctured. Only one periprocedural complication occurred, and it was unrelated to the use of sonographic guidance.

Conclusion: Sonographic guidance for central vein access via the right internal jugular vein is safer and more efficient than the traditional landmark approach.

PubMed Disclaimer

LinkOut - more resources