Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1998 Nov;70(5):972-81.
doi: 10.1016/s0015-0282(98)00278-7.

Serum human chorionic gonadotropin measurement in the diagnosis of ectopic pregnancy when transvaginal sonography is inconclusive

Affiliations
Free article
Clinical Trial

Serum human chorionic gonadotropin measurement in the diagnosis of ectopic pregnancy when transvaginal sonography is inconclusive

B W Mol et al. Fertil Steril. 1998 Nov.
Free article

Abstract

Objective: To assess the accuracy of initial and repeated serum hCG measurements in the diagnosis of ectopic pregnancy (EP) in patients in whom transvaginal sonography is inconclusive and to evaluate whether patient characteristics influence the accuracy of serum hCG measurements.

Design: Prospective study.

Setting: Two large teaching hospitals in Amsterdam, the Netherlands.

Patient(s): Three hundred fifty-four consecutively seen pregnant patients with suspected EP and inconclusive transvaginal sonographic findings.

Intervention(s): Serum hCG measurements.

Main outcome measure(s): The performance of repeated serum hCG measurements in the diagnosis of EP was evaluated through the analysis of receiver operating characteristic curves.

Result(s): Initial serum hCG measurements were more diagnostic in conjunction with sonographic evidence of an ectopic mass or fluid in the pouch of Douglas than in the absence of sonographic abnormalities. On repeated measurement, the course of the serum hCG concentration provided more diagnostic information than did the absolute serum hCG concentration 2 and 4 days after the start of the diagnostic process.

Conclusion(s): The interpretation of serum hCG measurements should depend on additional findings at transvaginal sonography. A cutoff level of 1,500 IU/L is recommended for patients with an ectopic mass or fluid in the pouch of Douglas; in patients without these findings, the cutoff level should be at least 2,000 IU/L. Four days after the start of the diagnostic process, any rise in the serum hCG concentration makes the diagnosis of EP very likely.

PubMed Disclaimer

Publication types

Substances