Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1998 Nov;32(5):1251-9.
doi: 10.1016/s0735-1097(98)00389-1.

Noninvasive assessment of coronary flow velocity and coronary flow velocity reserve in the left anterior descending coronary artery by Doppler echocardiography: comparison with invasive technique

Affiliations
Free article
Comparative Study

Noninvasive assessment of coronary flow velocity and coronary flow velocity reserve in the left anterior descending coronary artery by Doppler echocardiography: comparison with invasive technique

T Hozumi et al. J Am Coll Cardiol. 1998 Nov.
Free article

Abstract

Objectives: The purpose of this study was to evaluate whether transthoracic Doppler echocardiography (TTDE) can reliably measure coronary flow velocity (CFV) and coronary flow velocity reserve (CFVR) in the left anterior descending coronary artery (LAD) in the clinical setting.

Background: Coronary flow velocity measurement has provided useful clinical and physiologic information. Advancement in TTDE provides noninvasive measurement of CFV and CFVR in the distal LAD.

Methods: In 23 patients, CFV in the distal LAD was measured by TTDE (5 or 3.5 MHz) under the guidance of color Doppler flow mapping at the time of Doppler guide wire (DGW) examination. Coronary flow velocity in the distal LAD were measured at baseline and hyperemic conditions (intravenous administration of adenosine 0.14 mg/kg/min) by both TTDE and DGW techniques. Coronary flow velocity reserve was defined as the ratio of peak hyperemic to basal averaged peak velocity in the distal LAD.

Results: Clear envelopes of basal and hyperemic CFV in the distal LAD were obtained in 18 (78%) of 23 study patients by TTDE. There were excellent correlations between TTDE and DGW methods for the measurements of CFV (averaged peak velocity: r=0.97, y=0.94x + 0.40; averaged diastolic peak velocity: r=0.97, y=0.94x + 0.69; systolic peak velocities: r=0.97, y=0.91x + 0.87; diastolic peak velocity: r=0.98, y=0.95x + 1.10). Coronary flow velocity reserve from TTDE correlated highly with those from DGW examinations (r=0.94, y=0.95x + 0.21).

Conclusions: Noninvasive measurement of CFV and CFVR in the distal LAD using TTDE accurately reflects invasive measurement of CFV and CFVR by DGW method.