Evaluation of in situ fracture versus phaco chop techniques
- PMID: 9818335
- DOI: 10.1016/s0886-3350(98)80167-3
Evaluation of in situ fracture versus phaco chop techniques
Abstract
Purpose: To quantify and compare the phaco time required using in situ nucleofracture and phaco chop techniques.
Setting: Center for Research on Ocular Therapeutics and Biodevices and Miyake Laboratory, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA.
Methods: Thirty human eyes obtained postmortem were randomly divided into 2 groups of 15 eyes each. In situ nucleofracture or phaco chop was performed in each group. The phaco time required for each technique was determined.
Results: The mean phaco time was 0.91 minutes +/- 0.37 (SD) for the phaco chop and 1.56 +/- 0.89 minutes for the in situ fracture technique (P < .015).
Conclusions: The phaco chop technique reduced phaco time and total phaco power consumed during phacoemulsification without imposing a risk of intraoperative complications.
Comment in
-
Effective cataract surgery--an undervalued procedure.J Cataract Refract Surg. 1998 Nov;24(11):1417. doi: 10.1016/s0886-3350(98)80148-x. J Cataract Refract Surg. 1998. PMID: 9818320 No abstract available.
-
Comparing nuclear disassembly techniques.J Cataract Refract Surg. 1999 Apr;25(4):460-1. J Cataract Refract Surg. 1999. PMID: 10198844 No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials