Capsular bag distension associated with sulcus implantation of intraocular lenses
- PMID: 9818349
- DOI: 10.1016/s0886-3350(98)80181-8
Capsular bag distension associated with sulcus implantation of intraocular lenses
Abstract
Capsular bag distension syndrome after endophacoemulsification and in-the-bag intraocular lens (IOL) implantation has been reported. We describe 2 cases in which sulcus implantation of a posterior chamber IOL caused marked capsular bag distension. Both cases resolved with conservative treatment or a neodymium:YAG posterior capsulotomy.