Nosocomial and laboratory-acquired infection with Escherichia coli O157
- PMID: 9819689
- DOI: 10.1016/s0195-6701(98)90089-5
Nosocomial and laboratory-acquired infection with Escherichia coli O157
Abstract
Infections caused by verocytotoxigenic Escherichia coli O157 (VTEC O157) have emerged as a major public health concern. The nature and severity of associated clinical sequelae are such that symptomatic cases often require hospitalization, with possible exposure to other patients and healthcare workers, including laboratory personnel, to the risk of acquiring VTEC O157. The occurrence of such episodes of hospital- and laboratory-acquired infections has demonstrated that these concerns are justified. Hospital infection control teams must ensure that staff are aware of this potential hazard, and laboratories must review their operating procedures to ensure that their personnel are not unnecessarily exposed, particularly in the light of revised guidance on the safe handling of these organisms.
Similar articles
-
Four laboratory-associated cases of infection with Escherichia coli O157:H7.J Clin Microbiol. 2005 Jun;43(6):2938-9. doi: 10.1128/JCM.43.6.2938-2939.2005. J Clin Microbiol. 2005. PMID: 15956425 Free PMC article.
-
Laboratory-acquired VTEC infection.J Hosp Infect. 1997 Jan;35(1):72. doi: 10.1016/s0195-6701(97)90171-7. J Hosp Infect. 1997. PMID: 9032639 No abstract available.
-
Laboratory acquired verotoxin producing Escherichia coli (VTEC) infection.J Hosp Infect. 1996 Jul;33(3):228-30. doi: 10.1016/s0195-6701(96)90008-0. J Hosp Infect. 1996. PMID: 8827511 No abstract available.
-
Clinical, microbiological and epidemiological aspects of Escherichia coli O157 infection.FEMS Immunol Med Microbiol. 1998 Jan;20(1):1-9. doi: 10.1111/j.1574-695X.1998.tb01105.x. FEMS Immunol Med Microbiol. 1998. PMID: 9514570 Review.
-
[Verotoxin-producing Escherichia coli (VTEC) and Escherichia coli O157:H7 in medicine and food industry].Ann Biol Clin (Paris). 1999 Sep-Oct;57(5):507-15. Ann Biol Clin (Paris). 1999. PMID: 10518052 Review. French.
Cited by
-
Biological Risks and Laboratory-Acquired Infections: A Reality That Cannot be Ignored in Health Biotechnology.Front Bioeng Biotechnol. 2015 Apr 28;3:56. doi: 10.3389/fbioe.2015.00056. eCollection 2015. Front Bioeng Biotechnol. 2015. PMID: 25973418 Free PMC article. Review.
-
Evidence-based biosafety: a review of the principles and effectiveness of microbiological containment measures.Clin Microbiol Rev. 2008 Jul;21(3):403-25. doi: 10.1128/CMR.00014-08. Clin Microbiol Rev. 2008. PMID: 18625678 Free PMC article. Review.
-
Use of copper cast alloys to control Escherichia coli O157 cross-contamination during food processing.Appl Environ Microbiol. 2006 Jun;72(6):4239-44. doi: 10.1128/AEM.02532-05. Appl Environ Microbiol. 2006. PMID: 16751537 Free PMC article.
-
Laboratory-acquired infections.Clin Infect Dis. 2009 Jul 1;49(1):142-7. doi: 10.1086/599104. Clin Infect Dis. 2009. PMID: 19480580 Free PMC article. Review.
-
Four laboratory-associated cases of infection with Escherichia coli O157:H7.J Clin Microbiol. 2005 Jun;43(6):2938-9. doi: 10.1128/JCM.43.6.2938-2939.2005. J Clin Microbiol. 2005. PMID: 15956425 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical