. 1998 Nov;114(5):1283-8.
doi: 10.1378/chest.114.5.1283.

The accuracy and interobserver agreement in detecting the 'gallop sounds' by cardiac auscultation

Affiliations

The accuracy and interobserver agreement in detecting the 'gallop sounds' by cardiac auscultation

C E Lok et al. Chest. 1998 Nov.

Abstract

Study objectives: To determine the observer accuracy and interobserver agreement in identifying S4 and S3 by cardiac auscultation and whether they improve with increasing observer experience.

Design: Prospective, blinded study.

Setting: Cardiology and general internal medicine wards in a university-affiliated teaching hospital.

Patients: Forty patients with a cardiac diagnosis and 6 patients without were studied.

Measurements and results: Two cardiologists, one general internist, three senior and two junior postgraduate internal medicine trainees, blinded to the patients' characteristics, examined the patients and documented their findings on a questionnaire. Computerized phonocardiogram was obtained in all patients as a gold standard and was interpreted by a blinded, independent cardiologist. The mean positive predictive values for S4 and S3 were 51% (range, 24 to 100%) and 71% (range, 50 to 88%), respectively. The mean negative predictive values for S4 and S3 were 82% (range, 67 to 94%) and 64% (range, 56 to 85%), respectively. The overall interobserver agreements for detecting S4 was K = 0.05 (95% confidence interval [CI], 0.01 to 0.09) and S3 was K = 0.18 (95% CI, 0.13 to 0.24). There was no apparent trend in the accuracy or interobserver agreement with regard to the level of observer experience.

Conclusion: The agreement between observers and the phonocardiographic gold standard in the correct identification of S4 and S3 was poor and the lack of agreement did not appear to be a function of the experience of the observers. The overall interobserver agreement for the detection of either S4 or S3 was little better than chance alone.

PubMed Disclaimer

Comment in

  • In defense of the stethoscope.
    Adolph RJ. Adolph RJ. Chest. 1998 Nov;114(5):1235-7. doi: 10.1378/chest.114.5.1235. Chest. 1998. PMID: 9823993 No abstract available.
  • Audibility of fourth heart sound.
    Spodick DH. Spodick DH. Chest. 1999 Apr;115(4):1218-9. doi: 10.1378/chest.115.4.1218-a. Chest. 1999. PMID: 10208241 No abstract available.