The performance of CA-125 measurement in the detection of endometriosis: a meta-analysis
- PMID: 9848302
- DOI: 10.1016/s0015-0282(98)00355-0
The performance of CA-125 measurement in the detection of endometriosis: a meta-analysis
Abstract
Objective: To assess the diagnostic performance of serum CA-125 measurement in the detection of endometriosis.
Design: Meta-analysis.
Setting and patient(s): Twenty-three studies comparing serum CA-125 levels and laparoscopically confirmed endometriosis.
Intervention(s): Serum CA-125 measurement and laparoscopy.
Main outcome measure(s): Sensitivity and specificity of serum CA-125 measurement in the diagnosis of endometriosis with laparoscopy as the reference standard.
Result(s): The estimated summary receiver operating characteristic curves showed that the performance of serum CA-125 measurement in the diagnosis of endometriosis grade I/IV is limited, whereas its performance in the diagnosis of endometriosis grade III/IV is better.
Conclusion(s): Despite its limited diagnostic performance, we believe that the routine use of serum CA-125 measurement in patients with infertility might be justified. In contrast to laparoscopy, serum CA-125 measurement is an inexpensive test that is not a burden for the patient. It could identify a subgroup of patients who are more likely to benefit from early laparoscopy. Studies reporting on the mutual dependence between serum CA-125 measurement and data from the history and physical examination are needed.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials
Miscellaneous