Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1998 Dec;75(12):887-96.
doi: 10.1097/00006324-199812000-00011.

Repeatability of refraction and corrected visual acuity in keratoconus. The CLEK Study Group. Collaborative Longitudinal Evaluation of Keratoconus

Affiliations
Clinical Trial

Repeatability of refraction and corrected visual acuity in keratoconus. The CLEK Study Group. Collaborative Longitudinal Evaluation of Keratoconus

L J Davis et al. Optom Vis Sci. 1998 Dec.

Abstract

Purpose: The purpose of the test-retest phase of the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study was to determine the repeatability of the various parts of the CLEK Study protocol. This paper presents the test-retest parameters of the refraction protocol.

Methods: We examined 138 CLEK Study-eligible patients on two occasions (median, 90 days; range, 22 to 268 days). All patients underwent subjective refraction on two occasions, and contact lens over-refractions were performed either over the patient's habitual rigid contact lenses or over a trial rigid contact lens equal in base curve to the steep keratometric reading in nonrigid contact lens wearers.

Results: Mean interoccasion differences +/- SD were -0.32 +/- 2.91 D and -0.17 +/- 1.39 D for subjective refraction sphere and cylinder power, respectively, and the mean absolute difference for subjective refraction cylinder axis was 18.1 +/- 20.2 degrees. The mean interoccasion difference +/- SD for high-contrast visual acuity with subjective refraction was 0.38 +/- 10.9 letters correct. Mean interoccasion differences +/- SD were -0.11 +/- 0.81 D and 0.02 +/- 0.67 D for contact lens over-refraction sphere and cylinder power, respectively, and the mean absolute difference for contact lens over-refraction cylinder axis was 11.6 +/- 9.9 degrees. The mean interoccasion difference +/- SD for visual acuity with contact lens over-refraction was 0.50 +/- 5.2 letters correct and 0.71 +/- 6.9 letters correct for high- and low-contrast visual acuity, respectively.

Conclusions: The repeatability of subjective refraction in keratoconus patients is good but somewhat lower than that found in nondiseased eyes. Only 36% of our repeat measures of sphere power from subjective refraction fell within 0.50 D of each other, compared with more than 90% in studies of normal eyes.

PubMed Disclaimer

Publication types

LinkOut - more resources