Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1998 Dec;13(8):890-5.
doi: 10.1016/s0883-5403(98)90195-4.

Assessing activity in joint replacement patients

Affiliations
Comparative Study

Assessing activity in joint replacement patients

C A Zahiri et al. J Arthroplasty. 1998 Dec.

Abstract

Outcome evaluations of lower extremity joint reconstructions should include an assessment of patient activity. In vivo wear assessments of total joint prostheses should be based on a measure of use, not time in situ or a proxy such as age or gender; however, clinicians lack a simple method to reliably assess the activity of patients with joint replacement. The modern pedometer can be a satisfactory means of quantifying the use of lower extremity joints. The pedometer, however, requires special effort on the part of the physician or evaluator and the patient. Therefore, we compared the quantitative assessment of walking activity of 100 total joint replacement patients, as measured with a pedometer, to the UCLA activity score and a simple visual analog scale that can easily be employed during a routine office evaluation. Both the UCLA activity rating (P = .002) and the visual analog scale rating of the investigator (P = .00001) had a strong correlation with the average steps per day as recorded by the pedometer. There was, however, up to a 15-fold difference in the average steps per day for individual patients with the same UCLA score. The visual analog scale as rated by the patients of their own activity did not have as strong a correlation with the pedometer data (P = .08) as did patient age (P = .049). For practical reasons, the pedometer is probably best reserved for the evaluation of extreme cases of activity (or inactivity). This study indicates that both the UCLA activity rating and the investigator visual analog scale are valid for routine activity assessment in a clinical setting. Adjustments of the UCLA activity score for the frequency and intensity of activity, as can be done with the investigator visual analog scale, increase the accuracy of the activity rating.

PubMed Disclaimer

Comment in

  • Patient-reported outcome measures in arthroplasty registries.
    Rolfson O, Eresian Chenok K, Bohm E, Lübbeke A, Denissen G, Dunn J, Lyman S, Franklin P, Dunbar M, Overgaard S, Garellick G, Dawson J; Patient-Reported Outcome Measures Working Group of the International Society of Arthroplasty Registries. Rolfson O, et al. Acta Orthop. 2016 Jul;87 Suppl 1(Suppl 1):3-8. doi: 10.1080/17453674.2016.1181815. Epub 2016 May 11. Acta Orthop. 2016. PMID: 27168175 Free PMC article.

Publication types

LinkOut - more resources