Radiological demarcation of cemented sockets in total hip replacement
- PMID: 991504
Radiological demarcation of cemented sockets in total hip replacement
Abstract
The frequency of radiological demarcation of the cement-bone junction in the acetabulum after total hip replacement has been examined in 141 Charnley low-friction arthroplasties followed for an average of 10.1 years. Sixty-nine per cent showed demarcation of various degrees and 9.2 per cent of the series showed evidence of progressive migration of the socket. The vast majority of cases with demarcation were symptomless. In most cases where demarcation was accompanied by migration the operation notes suggested a technical explanation and in three cases low-grade sepsis was responsible. The fact that nearly 30 per cent of cases showed no demarcation even after 10 years supports the idea that there is no fundamental defect in the principle of employing cement in the acetabulum. Better surgical technique may increase the number of cases showing no demarcation.
Similar articles
-
The correlation between the roentgenographic appearance and operative findings at the bone-cement junction of the socket in Charnley low friction arthroplasties.Clin Orthop Relat Res. 1988 Mar;(228):105-9. Clin Orthop Relat Res. 1988. PMID: 3342551
-
Risk factors affecting radiological failure of the socket in primary Charnley low friction arthroplasty. A 10- to 20-year followup study.Clin Orthop Relat Res. 1994 Sep;(306):84-96. Clin Orthop Relat Res. 1994. PMID: 8070215 Review.
-
The results of Charnley arthroplasty of hip performed for protrusio acetabuli.Clin Orthop Relat Res. 1978 May;(132):12-8. Clin Orthop Relat Res. 1978. PMID: 679527
-
Radiology of total hip replacements.Clin Orthop Relat Res. 1976 Nov-Dec;(121):74-82. Clin Orthop Relat Res. 1976. PMID: 825342
-
Incidence and mechanism of failure of cemented acetabular component in total hip arthroplasty.Orthop Clin North Am. 1988 Jul;19(3):557-66. Orthop Clin North Am. 1988. PMID: 3288934 Review.
Cited by
-
Does vacuum mixing affect diameter shrinkage of a PMMA cement mantle during in vitro cemented acetabulum implantation?Proc Inst Mech Eng H. 2021 Feb;235(2):133-140. doi: 10.1177/0954411920964023. Epub 2020 Oct 15. Proc Inst Mech Eng H. 2021. PMID: 33054541 Free PMC article.
-
Long-term survival of the uncemented Balgrist total hip replacement cup.Int Orthop. 2013 Aug;37(8):1449-56. doi: 10.1007/s00264-013-1946-x. Epub 2013 Jun 8. Int Orthop. 2013. PMID: 23744502 Free PMC article.
-
Total hip replacement arthroplasty with Mallory-Head system--minimum ten-year follow-up results.Int Orthop. 2012 Oct;36(10):2055-9. doi: 10.1007/s00264-012-1627-1. Epub 2012 Aug 4. Int Orthop. 2012. PMID: 22864458 Free PMC article.
-
Radiographic assessment of radiolucent lines around a highly porous titanium cup (Tritanium) using digital tomosynthesis, after total hip arthroplasty.J Orthop Surg Res. 2021 Apr 15;16(1):266. doi: 10.1186/s13018-021-02396-4. J Orthop Surg Res. 2021. PMID: 33858459 Free PMC article.
-
Migration and head penetration of Vitamin-E diffused cemented polyethylene cup compared to standard cemented cup in total hip arthroplasty: study protocol for a randomised, double-blind, controlled trial (E1 HIP).BMJ Open. 2016 Jul 7;6(7):e010781. doi: 10.1136/bmjopen-2015-010781. BMJ Open. 2016. PMID: 27388352 Free PMC article. Clinical Trial.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical