Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1998 Dec 11;224(1-3):69-80.
doi: 10.1016/s0048-9697(98)00348-9.

Seasonal deposition of housedusts onto household surfaces

Affiliations

Seasonal deposition of housedusts onto household surfaces

R D Edwards et al. Sci Total Environ. .

Abstract

Seasonal differences in the particle size fractions and mass loadings of household dust deposited on indoor surfaces were examined in four New Jersey homes. Housedust was collected during a 30-day period on non-electrostatic polyethylene sample plates on which a glass slide had been placed. In each home two samples were collected at a height of 1.5 m and two were collected at a height of 0.3 m above the floor. Dust samples were obtained from each home during a summer and winter collection period. Particle size measurement was completed using an adaptation of a Meridian ACAS 570 Interactive Laser Cytometer. Results indicated that the dust mass deposited on household surfaces during the summer was greater than during the winter. The arithmetic mean mass deposition rate for all houses was 0.37 +/- 0.13 microgram/cm2/day during the summer and 0.22 +/- 0.13 microgram/cm2/day during the winter. The total number of particles deposited, however, was greater during the winter than during the summer. The increase in winter time particle number was caused by greater numbers of particles with an equivalent spherical diameter < 2.5 microns. The most probable source of these particles was winter time combustion emissions within the residences and the subsequent particle deposition on household surfaces. The greater mass loadings measured on the low sampling plates during the summer were associated with a greater number of particles with an equivalent spherical diameter > 5 microns. In the winter, however, the particle mass and number loadings were similar at both heights. These results suggested that ventilation of the house during the summer allowed resuspended particles to enter which led to the higher levels of settled dust. Measurement of contaminant levels in housedust for exposure estimation therefore, should account for the seasonal and height differences in dust mass, and collect representative fractions of housedust that are available for human contact. Furthermore, since over 99% of the particles on indoor surfaces were < 50 microns any indirect sampling technique for dermal exposure estimation should have collection efficiencies similar to the hand of particles < 50 microns.

PubMed Disclaimer

Publication types

LinkOut - more resources