Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1999 Jan;31(1):183-8.
doi: 10.1097/00005768-199901000-00028.

Accuracy of prediction equations to estimate submaximal VO2 during cycle ergometry: the HERITAGE Family Study

Affiliations

Accuracy of prediction equations to estimate submaximal VO2 during cycle ergometry: the HERITAGE Family Study

P R Stanforth et al. Med Sci Sports Exerc. 1999 Jan.

Abstract

It was hypothesized that more accurate equations for estimating submaximal VO2 during cycle ergometry could be developed if more independent variables were used in the equation.

Purpose: The purposes of this study were: (1) to develop new equations for estimating submaximal VO2 during cycle ergometry; and (2) to examine the accuracy of the newly developed equations and those of the American College of Sports Medicine (1995), Berry et al. (1993), Lang et al. (1992), Latin and Berg (1994), and Londeree et al. (1997).

Methods: Subjects (715 men and women, ages 16-65 yr, from the HERITAGE Family Study) completed a maximal cycle ergometry test, two submaximal trials at 50 W and 60% of VO2max, hydrostatic weighing, and stature and body mass measures before and after 20 wk of cycle ergometry training. Regression analysis generated prediction equations using pretraining data from the 60% trials.

Results: No equation with more independent variables was better than an equation that used only power output. This equation, HERITAGE-1, with only power output was cross-validated using the "jackknife" technique. Paired t-tests, mean differences, SEEs, and Es were used to compare the VO2 estimated by HERITAGE-1 and those of previously published equations with the measured VO2 at 60% of VO2max.

Conclusions: HERITAGE-1 was slightly better than the equations of ACSM, Lang et al., and Latin and Berg using pretraining data but was not better when using post-training data. All four of these equations were superior to the equations of Berry et al. and Londeree et al.

PubMed Disclaimer

Publication types

LinkOut - more resources