Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1999 Feb;159(2):383-8.
doi: 10.1164/ajrccm.159.2.9707046.

Changes in the work of breathing induced by tracheotomy in ventilator-dependent patients

Affiliations
Comparative Study

Changes in the work of breathing induced by tracheotomy in ventilator-dependent patients

J L Diehl et al. Am J Respir Crit Care Med. 1999 Feb.

Abstract

Tracheotomy is widely performed on ventilator-dependent patients, but its effects on respiratory mechanics have not been studied. We measured the work of breathing (WOB) in eight patients before and after tracheotomy during breathing at three identical levels of pressure support (PS): baseline level (PS-B), PS + 5 cm H2O (PS+5), and PS - 5 cm H2O (PS-5). After the procedure, we also compared the resistive work induced by the patients' endotracheal tubes (ETTs) and by a new tracheotomy cannula in an in vitro bench study. A significant reduction in the WOB was observed after tracheotomy for PS-B (from 0.9 +/- 0.4 to 0.4 +/- 0.2 J/L, p < 0.05), and for PS-5 (1.4 +/- 0.6 to 0.6 +/- 0.3 J/L, p < 0.05), with a near-significant reduction for PS+5 (0.5 +/- 0.5 to 0.2 +/- 0.1 J/L, p = 0.05). A significant reduction was also observed in the pressure-time index of the respiratory muscles (181 +/- 92 to 80 +/- 56 cm H2O. s/min for PS-B, p < 0.05). Resistive and elastic work computed from transpulmonary pressure measurements decreased significantly at PS-B and PS-5. A significant reduction in occlusion pressure and intrinsic positive end-expiratory pressure (PEEP) was also observed for all conditions, with no significant change in breathing pattern. Three patients had ineffective breathing efforts before tracheotomy, and all had improved synchrony with the ventilator after the procedure. In vitro measurements made with ETTs removed from the patients, with new ETTs, and with the tracheotomy cannula showed that the cannula reduced the resistive work induced by the artificial airway. Part of these results was explained by a slight, subtle reduction of the inner diameter of used ETTs. We conclude that tracheotomy can substantially reduce the mechanical workload of ventilator-dependent patients.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources