Abstract
Background: Exercise electrocardiography is an perfect test for the detection of coronary artery disease. We attempted to improve the diagnostic accuracy of exercise testing as a noninvasive method for the detection of coronary artery disease by using a combination of the left and right precordial leads.
Methods: We studied 245 patients (218 men and 27 women) ranging from 32 to 74 years of age (mean [+/-SD], 52+/-8) who underwent treadmill exercise testing, thallium-201 scintigraphy, and coronary arteriography. During exercise testing, each patient had one electrocardiogram recorded with the standard 12 leads and 3 right precordial leads (V3R, V4R, and V5R), with the results for each set of leads recorded and analyzed separately.
Results: On the basis of coronary arteriography, 34 patients had normal coronary arteries, 85 had single-vessel disease, 84 had two-vessel disease, and 42 had three-vessel disease. The sensitivities of the standard 12-lead exercise electrocardiogram, exercise electrocardiography incorporating right precordial leads, and thallium-201 scintigraphy were 52 percent, 89 percent, and 87 percent, respectively, for the detection of single-vessel disease; 71 percent, 94 percent, and 96 percent for the detection of two-vessel disease; 83 percent, 95 percent, and 98 percent for the detection of three-vessel disease; and 66 percent, 92 percent, and 93 percent for the detection of any coronary artery disease. The specificities of the three methods for the detection of any coronary artery disease were 88 percent, 88 percent, and 82 percent, respectively.
Conclusions: Use of right precordial leads along with the standard six left precordial leads during exercise electrocardiography greatly improves the sensitivity of exercise testing for the diagnosis of coronary artery disease.
Comment in
- ACP J Club. 1999 Sep-Oct;131(2):46
-
The value of the right precordial leads of the electrocardiogram.N Engl J Med. 1999 Feb 4;340(5):381-3. doi: 10.1056/NEJM199902043400510. N Engl J Med. 1999. PMID: 9929531 No abstract available.
-
Exercise electrocardiography with right precordial leads.N Engl J Med. 1999 Jul 15;341(3):208; author reply 209. doi: 10.1056/NEJM199907153410315. N Engl J Med. 1999. PMID: 10409040 No abstract available.
-
Exercise electrocardiography with right precordial leads.N Engl J Med. 1999 Jul 15;341(3):208; author reply 209-10. N Engl J Med. 1999. PMID: 10409041 No abstract available.
-
Exercise electrocardiography with right precordial leads.N Engl J Med. 1999 Jul 15;341(3):209-10. N Engl J Med. 1999. PMID: 10409043 No abstract available.
-
Use of right precordial leads during exercise testing.N Engl J Med. 2000 Sep 28;343(13):968-9. doi: 10.1056/NEJM200009283431312. N Engl J Med. 2000. PMID: 11012323 No abstract available.
Similar articles
-
Do the right precordial leads during exercise testing contribute to detection of coronary artery disease?Clin Cardiol. 2004 Feb;27(2):101-5. doi: 10.1002/clc.4960270214. Clin Cardiol. 2004. PMID: 14979632 Free PMC article.
-
Failure of right precordial electrocardiography during stress testing to identify coronary artery disease.J Nucl Cardiol. 2001 May-Jun;8(3):325-31. doi: 10.1067/mnc.2001.112855. J Nucl Cardiol. 2001. PMID: 11391302
-
Comparison of thallium-201 single-photon emission computed tomography and electrocardiographic response during exercise in patients with normal rest electrocardiographic results.J Am Coll Cardiol. 1995 Mar 15;25(4):830-6. doi: 10.1016/0735-1097(94)00471-2. J Am Coll Cardiol. 1995. PMID: 7884084 Clinical Trial.
-
Improved detection of coronary artery disease by exercise electrocardiography with the use of right precordial leads.J Insur Med. 1999;31(1):39-40. J Insur Med. 1999. PMID: 10539389 Review. No abstract available.
-
Toward the optimal lead system and optimal criteria for exercise electrocardiography.Am J Cardiol. 1981 Jun;47(6):1366-74. doi: 10.1016/0002-9149(81)90270-8. Am J Cardiol. 1981. PMID: 7015818 Review.
Cited by
-
Detection of Acute Myocardial Infarction in a Pig Model Using the SAN-Atrial-AVN-His (SAAH) Electrocardiogram (ECG), Model PHS-A10, an Automated and Integrated Signals Recognition System.Med Sci Monit. 2018 Mar 4;24:1303-1309. doi: 10.12659/msm.905961. Med Sci Monit. 2018. PMID: 29502127 Free PMC article.
-
Right-sided chest leads in exercise testing for detection of coronary restenosis.Clin Cardiol. 2010 Apr;33(4):236-40. doi: 10.1002/clc.20609. Clin Cardiol. 2010. PMID: 20162735 Free PMC article.
-
Identification of the Vessels Causing Myocardial Ischemia by a Synthesized 18-Lead Electrocardiogram Obtained After the Master Two-Step Exercise Test in a Patient With Effort Angina.Cureus. 2023 Oct 27;15(10):e47840. doi: 10.7759/cureus.47840. eCollection 2023 Oct. Cureus. 2023. PMID: 38022094 Free PMC article.
-
Do the right precordial leads during exercise testing contribute to detection of coronary artery disease?Clin Cardiol. 2004 Feb;27(2):101-5. doi: 10.1002/clc.4960270214. Clin Cardiol. 2004. PMID: 14979632 Free PMC article.
-
Computer applications in the interpretation of the exercise electrocardiogram.Sports Med. 2000 Oct;30(4):231-48. doi: 10.2165/00007256-200030040-00001. Sports Med. 2000. PMID: 11048772 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources