Objective: Arterial pulse pressure variation (PPV) has been used as an accurate index to predict fluid responsiveness. However, many confounding factors have been recently described. The aims of this study were to assess the conditions of applicability of PPV in intensive care units (ICU).
Study design: A one-day French national survey.
Patients and methods: A form assessing the suitability of PPV was completed by practitioners for each critically-ill patient included on a set day.
Results: Four hundred and sixty-five patients were included in 36 ICUs. A regular sinus rhythm was noted in 408 (88%) patients and the presence of an arterial line in 324 (70%) patients. One hundred and twenty-seven (27%) patients were mechanically ventilated without spontaneous breathing. Only six patients (1.3%) had no confounding factors modifying the threshold value of the PPV.
Conclusion: The incidence of ICU patients in whom PPV was suitable and without confounding factors were respectively 18% and 1.3% in this one-day French national survey.
Keywords: Critical care; Monitoring; Predicting fluid responsiveness; Pulse pressure variation; Survey.
Copyright © 2015 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.
Comment in
-
Pulse pressure respiratory variation to predict fluid responsiveness: From an enthusiastic to a rational view.Anaesth Crit Care Pain Med. 2015 Feb;34(1):9-10. doi: 10.1016/j.accpm.2015.02.002. Epub 2015 Mar 18. Anaesth Crit Care Pain Med. 2015. PMID: 25829308 No abstract available.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical