Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2017 Oct:158:126-133.
doi: 10.1016/j.thromres.2017.09.001. Epub 2017 Sep 4.

Evaluation of dabigatran, rivaroxaban and apixaban target-specific assays in a multicenter French study

Collaborators, Affiliations
Multicenter Study

Evaluation of dabigatran, rivaroxaban and apixaban target-specific assays in a multicenter French study

Isabelle Gouin-Thibault et al. Thromb Res. 2017 Oct.

Abstract

Dabigatran etexilate, rivaroxaban and apixaban (DOACs) are widely used and measurement of their concentration is desirable in certain clinical situations. Target-specific assays are available but limited information exists on their performance especially in their ability to accurately measure low and high concentrations.

Aims: To define, in a multicenter study, the precision and accuracy of DOAC measurements in daily practice.

Methods: 15 plasma samples (kindly provided by Hyphen-Biomed) spiked with 5 blinded concentrations of dabigatran, rivaroxaban or apixaban (targeted 0-40-100-250-500ng/mL, actual concentrations measured by HPLC-MS/MS), were sent to 30 haemostasis laboratories. DOAC concentration, PT and aPTT were measured once in each sample using local reagents. Interlaboratory precision was determined by its coefficient of variation (CV) and accuracy by its bias.

Results: 464 DOAC measurements were performed in the 30 laboratories using 4 dabigatran and 5 rivaroxaban/apixaban calibrated assays on 3 analysers. Inter-laboratory CVs were below 18% for concentrations ≥100ng/mL, and higher for concentrations ~40ng/mL; biases were below 8% for all drugs and concentrations. In DOAC-free samples, concentrations were all below the lower limit of quantification except for one value (dabigatran: 35ng/mL). Depending on the concentrations, significant differences were found between reagents in rivaroxaban and apixaban concentration values. PT and aPTT ratios displayed a low sensitivity to apixaban.

Conclusion: Our results suggest that calibrated DOAC assays allow the reliable measurement of a wide range of drug concentrations, even though improvement of their performances is necessary, especially for measuring low concentrations.

Keywords: Anti-Xa activity; DOAC measurement; Dilute thrombin time; Direct factor Xa inhibitor; Direct thrombin inhibitor; Ecarin assay; PT; aPTT.

PubMed Disclaimer

Publication types