. 2022 Feb;36(1):93-101.
doi: 10.1007/s10877-020-00624-6. Epub 2021 Jan 2.

Prediction of reactivity during tracheal intubation by pre-laryngoscopy tetanus-induced ANI variation

Affiliations

Prediction of reactivity during tracheal intubation by pre-laryngoscopy tetanus-induced ANI variation

Elsa Jozefowicz et al. J Clin Monit Comput. 2022 Feb.

Abstract

The ANI is a nociception monitor based on the high frequency parts of heart rate variability. Tracheal intubation may induce potentially deleterious hemodynamic disturbances or motor reactions if analgesia is inadequate. We investigated whether ANI modification generated by a standardized moderate short tetanic stimulation performed before laryngoscopy could predict hemodynamic or somatic reactions to subsequent intubation. We designed a prospective, interventional, monocentric, pilot study. Regional ethics board approved the study, written informed consent was obtained from each participant. Before laryngoscopy, under steady-state total intravenous anaesthesia with propofol and remifentanil, the ulnar nerve was stimulated with a 5 s tetanus (70 mA, 50 Hz). After another steady-state period, orotracheal intubation was performed. ANI variation, hemodynamic parameters and somatic reactions associated with tetanus and intubation were collected. To assess the predictability of hemodynamic or somatic reaction during laryngoscopy by tetanus-induced ANI variation, we calculated the area under the corresponding Receiver Operating Characteristic curve (AUCROC) and the 95% confidence intervals. Thirty-five patients were analyzed. ANI decreased by 21 ± 17 after tetanus. Regarding the ability of tetanus-induced ANI variation to predict hemodynamic or somatic reactions during subsequent intubation, the AUCROCs [95% CI] were 0.61 [0.41-0.81] and 0.52 [0.31-0.72] respectively. ANI varied after a short moderate tetanic stimulation performed before laryngoscopy but this variation was not predictive of a hemodynamic or somatic reaction during intubation.Trial registration NCT04354311, April 20th 2020, retrospectively registered.

Keywords: Analgesia Nociception Index; Monitoring; Nociception; Tracheal intubation.

PubMed Disclaimer

References

    1. Ledowski T. Objective monitoring of nociception: a review of current commercial solutions. Br J Anaesth. 2019;123(2):e312–21. - DOI
    1. Meijer FS, Niesters M, van Velzen M, Martini CH, Olofsen E, Edry R, Sessler DI, van Dorp ELA, Dahan A, Boon M. Does nociception monitor-guided anesthesia affect opioid consumption? A systematic review of randomized controlled trials. J Clin Monit Comput. 2019;20
    1. Jeanne M, Clement C, De Jonckheere J, Logier R, Tavernier B. Variations of the analgesia nociception index during general anaesthesia for laparoscopic abdominal surgery. J Clin Monit Comput. 2012;26(4):289–94. - DOI
    1. Ledowski T, Averhoff L, Tiong WS, Lee C. Analgesia Nociception Index (ANI) to predict intraoperative haemodynamic changes: results of a pilot investigation. Acta Anaesthesiol Scand. 2014;58(1):74–9. - DOI
    1. Kommula LK, Bansal S, Umamaheswara Rao GS. Analgesia nociception index monitoring during Supratentorial craniotomy. J Neurosurg Anesthesiol. 2019;31(1):57–61. - DOI